F-34

F-34

TROUBLESHOOTING & REPAIR

ABNORMAL OPEN CIRCUIT WELD VOLTAGE WAVEFORM

HIGH IDLE – NO LOAD – OUTPUT CONTROL AT MAXIMUM

CH1

0 volts

50 volts

5 ms

This is not the typical DC output voltage waveform. Note the “gap” in the waveform. One output diode was disconnected to simulate an “open” diode. Each vertical division repre- sents 50 volts and that each horizon- tal division represents 5 milliseconds in time.

Note: Scope probes connected at machine output terminals.

SCOPE SETTINGS

Volts/Div

50V/Div.

Horizontal Sweep

5 ms/Div.

Coupling

DC

Trigger

Internal

 

 

WELDANPOWER 125

Page 72
Image 72
Lincoln Electric SVM 113-A service manual Abnormal Open Circuit Weld Voltage Waveform