F-6

 

 

 

F-6

TROUBLESHOOTING & REPAIR

 

 

Observe Safety Guidelines

 

TROUBLESHOOTING GUIDE

detailed in the beginning of this manual.

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

No auxiliary power – welding out-

1. Make sure that the control

1. Check the auxiliary power

put is normal – engine runs nor-

rheostat (R1) is set at maxi-

receptacles and associated

mally.

mum.

wires for loose or faulty con-

 

2. Check for a loose or faulty plug

nections.

 

 

 

 

 

 

at the power receptacle.

2. Check the continuity (zero

 

3. If the machine is equipped with

ohms) of leads #3, #5, and #6

 

from

the receptacles

to the

 

circuit breakers, check and

 

main

stator windings.

See

 

reset if tripped.

 

Wiring Diagram.

 

 

 

 

 

 

3. Make sure lead #5 is grounded

 

 

to the machine frame (zero

 

 

ohms).

 

 

 

4. Perform the Main

Stator

 

 

Winding Test.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.