TROUBLESHOOTING & REPAIR

FIELD DIODE BRIDGE REMOVAL AND REPLACEMENT (continued)

FIGURE F.18 - FIELD DIODE BRIDGE LOCATION

Return to

Return to Section TOC

Return to

Return to Master TOC

7A (Blue)

201(Black) 201C (Black)

200(Red)

200C (Red)

+

9A (Brown)

Field Diode Bridge

9B (Brown)

 

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

5.The field diode bridge is mounted to the sheet metal just above the capacitor. See Figure F.18. Remove it using the slot head screw driver and the 11/32” wrench.

6.With the needle nose pliers, gently remove the 7 wires from the diode bridge.

7.Replace the wires to their appropriate loca- tions on the new diode bridge:

Lead 200 and 200C are piggy-backed to the positive (+) terminal. Depending on the bridge used, this corner may be beveled and/or marked with a + sign.

Lead 201 (Black) and 201B (Black) are piggy- backed on the negative (–) terminal, which will always be located diagonally across from the positive (+) terminal.

The Blue lead (7A) is attached to one AC ter- minal. Leads 9A and 9B are piggy-backed to the other AC terminal.

8.Mount the field diode bridge using the screw, washers and nut. Use the slot head screwdriver and 11/32” wrench.

9.Check that the leads are not grounded and for clearance and tightness.

10.Replace the control panel and tighten the 6 sheet metal screws with the 5/16” nut driver and 5/16” wrench.

11.Replace the top cover of the control box and tighten the 8 sheet metal screws with the 5/16” nut driver.