Table for DFSMS Library Failure Messages or Exception Conditions
Table12. DFSMS Messages Based on Library Failure or Exception Conditions
Resulting Console Message Action
CBR3711IUnexpected ERA code
ERA-code
from
library
library-name
.
An error has been detected during processing in tape
library
library-name
. The library returned a unit check with
error recovery action code
ERA-code
, which is an
unexpected or inappropriate response to the library
request.
It is likely that the microcode in the library and the
software are not at the correct level.
Contact your service representative.
CBR3712I Unexpected completion code, CC=
cc
, from
library
library-name
.
An error has been detected during processing in tape
library
library-name
.An unexpected or inappropriate
completion code
cc
has been received from the library.
It is likely that the microcode in the library and the
software are not at the correct level.
Contact your service representative.
CBR3721I Library
library-name
in manual mode.
Library
library-name
is in manual mode and cannot
complete or accept library audit requests.Any pending
audit requests queued within the library when it was
placed in manual mode are failed resulting in this
message.Any subsequent audit requests issued to the
library will also fail and result in this message.
When the library has returned to auto mode, resubmit the
audit requests.
CBR3722I Library
library-name
equipment check.
Alibrary hardware failure has been detected by the
library or one of the associated tape subsystems. The
failing library component must be repaired before library
requests can be completed successfully.
Contact your service representative.
CBR3724I Volume
volser
does not exist in library
library-name
.
Volume
volser
does not reside in library
library-name
.Itis
possible that the volume has been ejected from the
library by another host system.
1. Use the ISMF mountable tape volume list function to
examine the current state of the volume under
DFSMS.
2. Determine where the volume is and re-enter it into the
library’s input station.
CBR3725I Library
library-name
command reject for
volume
volser
. Library error code=
error-code
.
Arequest for a library operation with volume
volser
has
been rejected by library
library-name
. The error code
indicates the reason for the rejection, but is included for
diagnostic purposes only.
It is likely that the microcode in the library and the
software are not at the correct level.
Contact your system administrator.
Chapter8. Problem Determination Procedures 269