vVolumes present
vOpened
vUnknown
Convenience I/O Mode
Shows the mode setting for the Convenience I/O station. Possible mode
settings are:
vInsert
vImport
vUnknown
vnone (This field is blank if the Convenience I/O is not installed)
High-Capacity Output or Input/Output Status
Shows the status of the high-capacity facility. Not Inventoried indicates an
inventory operation must be performed before the number of empty
cartridge storage cells is known. Empty cells- x indicates the high-capacity
operation is complete and the number of empty cells that remain available
in the high-capacity facility. Failed indicates the high capacity output
operation failed. Cancelled indicates the operation was cancelled by an
operator. In Progress indicates either an Inventory Update that includes the
high-capacity rack is in progress or a high-capacity only Inventory Update
is in progress. Percent Complete indicates the progress of the high
capacity facility. Blank indicates the 3494 has not been taught. Not
Installed indicates the high-capacity facility was not defined when the 3494
was taught.
High Capacity Rack
Shows which rack contains either the high capacity output facility or the
high capacity input/output facility. Blank indicates the facility is not installed.
Inventory Update
Shows whether inventory update is installed. If inventory update is installed,
its operational status is displayed. Disabled indicates inventory update will
not be performed. Not started indicates an inventory update operation has
not been performed since the 3494 was initialized. Failed indicates the
inventory update operation failed. Cancelled indicates the inventory update
operation was cancelled by an operator. In progress indicates the inventory
update operation is in progress. Percent Complete indicates the progress
of the inventory update. Completed indicates the inventory update
operation has completed. An inventory update status panel is displayed
during the Inventory Update Operation (IUO). Refer to “Perform Inventory
Update (Partial)” on page 179. Blank indicates the 3494 has not been
taught.
Enclosure doors
Shows the status of the enclosure doors. The window displays Closed if
the front doors are closed. If any front door is open, the window displays
Open.
Overall system
Shows the overall subsystem status. OK indicates that the subsystem is
functional. Degraded indicates that some part of the subsystem failed but
the subsystem can function in a degraded manner. Use Operational status
and Component availability status from the Status pull-down for
additional information. (See “Operational Status” on page111.)
Standby LM (Library Manager)
Shows the status of the standby library manager. Enabled indicates the
132 Magstar 3494 TapeLibrary Operator Guide
|
|
|
|
|
|
|
|