Table 21. Intervention Required Conditions relating to cleaner cartridges (continued)

Intervention Required Condition

Resolution Actions

 

 

 

Message

1.

Place the library system in pause mode.

 

A mislabeled cleaner cartridge has been left in device

2.

Open the appropriate enclosure door.

 

 

xxx feed slot. Remove the cartridge.

3.

If the cartridge is accessible, remove it.

Probable Cause

4.

If the cartridge is in a 3490 device, make the device

 

not ready by pressing the Ready switch, press the

 

 

During a clean operation, tape device xxx determined that

 

Unload switch to unload the cartridge, remove the

 

cartridge, then make the device ready by pressing

the cleaner cartridge is not compatible with the device but

 

 

the Ready switch.

was not able to unload the cartridge. It is likely that the

 

5.

If the cartridge is in a 3590 device, select Unload

cartridge has a missing or damaged media type label or

the media type label is incorrect for the cartridge media

 

from the Options Menu and press Enter. Remove

type.

 

the cartridge.

 

6.

If unable to remove cartridge, call your service

 

 

representative.

 

7.

Close the enclosure door.

 

8.

Place the library system in auto mode.

 

9.

Inspect the cartridge's seventh character. Install the

 

 

correct seventh character representing the media

 

 

type. See the tape drive Operator's Guide for the

 

 

procedure.

 

10.

Place the cartridge in the convenience I/O station.

 

 

 

Table for Intervention Conditions of a Library Virtual Tape Server

Table 22. Intervention Required Conditions relating to a Virtual Tape Server in the Library

 

Intervention Required Condition

Resolution Actions

 

 

 

 

Message

1. Notify your system administrator.

 

 

 

Logical volume xxxxxx was not fully recovered from

 

 

damaged stacked volume yyyyyy. (VTS z)

 

 

Probable Cause

 

During the attempted movement of logical volume xxxxxx

 

from a damaged stacked volume which is in Read-only

 

mode, a permanent read error was encountered. The

 

error was not recoverable. The data associated with the

 

logical volume was not recovered, and was not moved to

 

another stacked volume.

 

 

 

 