Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type) (continued)

 

Parameter

Parameter

Parameter

Actual Library Manager OPINT Trap

OPINT #

[A]

[B]

[C]

Message

 

 

 

 

 

 

 

9

Volser

Ð

Ð

An unexpected volser (

[A]) was found and

 

 

 

 

ejected to the convenience I/O station.

 

 

 

 

 

10

Ð

Ð

Ð

*The high-capacity output rack is full.

 

 

 

 

 

11

Volser

Rack Cell

Ð

A duplicate volser ( [A]) was left in

 

 

 

 

high-capacity input rack cell [B]

 

 

 

 

 

12

Rack Cell

Ð

Ð

An unreadable volser was left in

 

 

 

 

high-capacity input rack cell [A]

 

 

 

 

 

13

Volser

Rack Cell

Ð

An invalid volser ( [A]) was left in

 

 

 

 

high-capacity input rack cell B

 

 

 

 

 

 

14

Volser

Ð

Ð

An invalid volser (

[A]) was left in the

 

 

 

 

convenience I/O station

 

 

 

 

 

 

15

Volser

Rack Cell

Ð

A duplicate volser ( [A]) was ejected to

 

 

 

 

high-capacity output rack cell [B]

 

 

 

 

 

16

Volser

Rack Cell

Ð

An unexpected volser ( [A]) was ejected to

 

 

 

 

high-capacity output rack cell [B]

 

 

 

 

 

 

17

Device

Ð

Ð

Load / unload failure on device

[A].

 

 

 

 

 

 

18

Volser

Ð

Ð

An unexpected volser (

[A]) was left in the

 

 

 

 

convenience I/O station.

 

 

 

 

 

 

19

Volser

Rack Cell

Ð

An unexpected volser ( [A]) was left in

 

 

 

 

high-capacity output rack cell [B]

 

 

 

 

 

20

Ð

Ð

Ð

*The convenience I/O station door is open.

 

 

 

 

 

21

Ð

Ð

Ð

*The convenience I/O station door is open.

 

 

 

 

 

22

Volser

Ð

Ð

Volser ( [A]) could not be put away. It was

 

 

 

 

ejected to the convenience I/O station.

 

 

 

 

 

23

Volser

Rack Cell

Ð

Volser ( [A]) could not be put away. It was

 

 

 

 

ejected to the high-capacity output rack cell

 

 

 

 

 

[B].

 

 

 

 

 

 

24

Ð

Ð

Ð

The convenience I/O station should be

 

 

 

 

empty but is not. Visually check the station.

 

 

 

 

 

25

Gripper

Accessor

Ð

A cartridge could not be released from

 

 

 

 

gripper [A] accessor [B].

 

 

 

 

 

 

 

26

Volser

Ð

Ð

A cartridge has been dropped. (

[A])

 

 

 

 

 

27

Ð

Ð

Ð

Environmental alert - Smoke has been

 

 

 

 

detected in the enclosure.

 

 

 

 

 

 

28

Ð

Ð

Ð

An emergency stop has occurred.

 

 

 

 

 

 

29

Volser

Ð

Ð

Damaged volser (

[A]) ejected to the

 

 

 

 

convenience I/O station.

 

 

 

 

 

 

30

Volser

Rack Cell

Ð

Damaged volser ( [A]) ejected to

 

 

 

 

high-capacity output facility cell: [B]

 

 

 

 

 

 

31

Device

Ð

Ð

Device [A] is not ready.

 

 

 

 

 

 

34

Device

Ð

Ð

A mislabeled cleaner cartridge has been left

 

 

 

 

in device [A] feed slot. Remove the

 

 

 

 

cartridge.

 

 

 

 

 

 

35

Device

Ð

Ð

A recoverable error occurred on device [A].

 

 

 

 

A service call may be needed if the error

 

 

 

 

persists.

 

 

 

 

 

 

 

 

 

Chapter 6. Advanced Operating Procedures 217