Using the High-Capacity Input/Output Facility

 

Attention: Never place Exported Stacked Volumes into the High Capacity

 

Input/Output Facility, as this will cause the data on them to be overwritten.

 

 

The de®ned facility will be scanned on the ®rst transition to Automatic mode even if

 

 

Inventory Update is disabled or on any transition to Automatic mode if the door

 

 

associated with the frame containing the facility has been opened. The scan is done

 

 

in the above cases regardless of the state of Inventory Update (enabled/disabled).

 

 

Following the scan of the facility, all library activity is restored (mounts, demounts,

 

 

conv. I/O). VOLSERS to be inserted are added to the database and the host is

 

 

noti®ed. Once the category has changed, the VOLSERS may be mounted directly

 

 

from the high capacity area.

 

 

New VOLSERs found in the facility are inserted and those already existing in the

 

 

facility are left ejected. VOLSERs are inserted from the facility in a top to bottom

 

 

and right to left sequence (E 01 to A xx). VOLSERs are ejected to the facility in a

 

 

top to bottom and left to right sequence (A 01 to E xx). The physical movement of

 

 

the cartridge is scheduled with regular library activity. The operator may change the

 

 

priority on a particular insert so movement will be completed faster.

 

 

Con®guring the High-Capacity I/O is done during a teach operation under theTeach

 

 

pull-down in Service mode.

 

 

Note: There should be enough free cells in the library to hold the cartridges that

 

 

must be moved when High-Capacity I/O is con®gured. When the facility is

 

 

moved to a new location, both the old location rack and the new location

 

 

rack are scanned.

 

 

 

 

 

Removing Ejected Cartridges

You may remove ejected cartridges from the library in the following ways:

vBy removing an ejected cartridge from the single-cell output facility

vBy removing an ejected cartridge from the High-Capacity Output facility or High-Capacity Input/Output facility

vBy removing an ejected cartridge from the Convenience Input¤Output Station feature

Notes:

1.The type of input¤output facility available to the operator was de®ned during installation of the library.

2.Avoid manually removing cartridges from library cells. Have the host eject them to an input/output facility.

Removing an Ejected Cartridge from the Single-Cell Output Facility

1.Press the Pause button on the operator panel.

2.Observe the Pause mode LED on the operator panel. The LED ¯ashes until the library is in Pause mode and then stays lit.

3.Unlock and open the control unit frame front door and retrieve the ejected cartridge from the single-cell output facility at location 2 A 1 (or location 2 A 3 if the optional Dual Gripper feature is installed).

4.Shut and lock the control unit frame door.

Chapter 5. Basic Operating Procedures 81

Page 103
Image 103
IBM Magstar 3494 manual Using the High-Capacity Input/Output Facility, Removing Ejected Cartridges