Table12. DFSMS Messages Based on Library Failure or Exception Conditions (continued)
Resulting Console Message Action
CBR3759E Library
library-name
safety enclosure
interlock open.
One of the enclosure doors to the library
library-name
is
open. The library is in pause mode.
This message is retained on the console until the safety
interlocks are closed.
1. If an operator is performing an operation that involves
entering the enclosure, no action is necessary.
2. If someone could be entering the enclosure without
authorization, contact your site security.Intervention
at the library is required to return the library to auto
mode.
CBR3760E Library
library-name
vision system not
operational.
Key components of the vision system of library
library-name
have failed. The library cannot read the
external labels on cartridges. Processing of audit or eject
requests cannot be performed.Also, volumes cannot be
added to the library because their external labels cannot
be read. Other requests continue to be accepted and
performed.
This message is retained on the console until the vision
system is operational again.
1. Contact your service representative to repair the
library vision system.
2. Resubmit audit or eject requests when the vision
system is operational.
CBR3761E Library
library-name
library manager
offline.
Library
library-name
started the process of going offline
as the result of an operator at the library manager
requesting the library move to the offline state.All
requests that have already been accepted by the library
manager are completed normally.No other requests are
accepted.
1. Determine why the library manager was placed in the
offline state.
2. If a repair action is required, contact your service
representative.
CBR3762E Library
library-name
intervention required.
One or more conditions in library
library-name
requires
operator intervention to resolve. Library function requests
continue to be accepted and executed, if possible. If this
message is accompanied by CBR3757E Library
library-name
in paused mode operational state, the
intervention condition caused automated operations to be
stopped.
This message is retained on the console until all
intervention-required conditions have been cleared.
1. Go to the library and follow the instruction for the
intervention-required condition specified on the library
manager operator console. See “Intervention
Required Conditions andActions” on page 282 for the
intervention-required conditions.
2. After all conditions are resolved, return the library to
auto mode, if required.
CBR3763E Library
library-name
library manager check
1 condition.
The library manager detected a severe failure condition in
library
library-name
.All requests that were accepted by
the library manager are lost.
1. Go to the library and see if the library manager is
trying to recover.If it is, the library manager console
is displaying an initialization message. If it is not, it is
displaying an execution or fatal error message.
2. If the library manager recovers, resubmit all
outstanding library requests or jobs.
3. If it does not recover, contact your service
representative.
Chapter8. Problem Determination Procedures 273