remains lit when in Auto mode. If the mode transition cannot be completed, the Intervention Required LED will light.

„8… Pause mode switch and status LED

The Pause mode motion control switch allows the operator to place the library into Pause mode. The LED ¯ashes during the mode transition and remains lit when in Pause mode. If the mode transition cannot be completed, the Intervention Required LED will light.

„9… Intervention Required LED

The Intervention Required LED, when lit, indicates operator interventions are required. See ªOperator Interventionº on page 199 for instructions to perform operator interventions.

A 0 6 C 0 0 6 5

Figure 22. Operator Panel without Convenience Input¤Output Station Feature

Convenience Input¤Output Station Status Indicators

If the Convenience Input¤Output Station feature is installed on the 3494, four additional status lights are present on the operator panel. See Figure 23 on page 34 for the locations of the controls and the indicators.

„1… Input Mode

The Input Mode LED, when lit, indicates that cartridges are in the

Convenience Input¤Output Station and the station is in Input mode.

„2… Output Mode

The Output Mode LED, when lit, indicates that cartridges are being ejected from the library into the Convenience Input¤Output Station.

„3… Unload Required

The Unload Required LED, when lit, indicates that the Convenience

Input¤Output Station has ejected cartridges that need to be removed.

Chapter 2. Controls and Indicators 33

Page 55
Image 55
IBM Magstar 3494 manual Convenience Input¤Output Station Status Indicators