Library Manager Screens (MVS/BLTS Environment)

A library manager failure causes the library manager console to display certain messages. If the failure has not affected the display and the display is powered on, the library manager may display one or more of the following screen messages:

Single Library Manager Con®guration: v `Severe execution error' dialog box

v System hang with non-responsive library manager keyboard or mouse

Note: If this occurs, press Alt-tto make sure the keyboard and display are not being controlled from the remote console.

 

v Mode changes which show Pending for an excessive length of time

 

v Error recovery in progress

 

Dual Library Manager Con®guration:

 

v Switching to active library manager dialog box displayed

 

v `Severe execution error' dialog box

 

v System hang with non-responsive library manager keyboard or mouse

 

Note: If this occurs, press ALT+T to make sure the keyboard and display are not

 

being controlled from the remote console.

To manually restart a library manager, go to ªLibrary Manager Action ± Library

Manager Recovery Begins (MVS/BLTS Environment)º.

Start the Library Manager and Host Recovery Procedure (MVS/BLTS Environment)

Follow each step of the following procedure without deviation.

Library Manager Action ± Library Manager Recovery Begins (MVS/BLTS Environment)

Single Library Manager Con®guration: For a single library manager con®guration, do the following:

1.Contact host operations and inform them what has occurred at the library manager.

2.If a BTLS ERA=70 Library Manager Equipment Check occurred, the library manager automatically attempts to restart itself.

The library manager should begin initial program load (IPL) in about 5 minutes and may take up to 20 minutes to complete and become active. If, after 5 minutes, there is no change in the System Status messages, or an ªError recovery in progressº message is not displayed, do a manual restart. Do not power off the library manager. Press the CTL+ALT+DEL key sequence to restart the library manager.

This procedure may need to be repeated. If the library manager fails to begin IPL in 5 minutes, after the second attempt to recover call your next level of support.

3.If the failure did not cause the Library Manager to automatically restart, perform the CTL+ALT+DEL key sequence to restart the library manager.

266Magstar 3494 Tape Library Operator Guide

Page 288
Image 288
IBM Magstar 3494 manual Library Manager Screens MVS/BLTS Environment