IBM Magstar 3494 manual Mount of logical volume xxxxxx failed because

Models: Magstar 3494

1 378
Download 378 pages 54 Kb
Page 322
Image 322

Table 22. Intervention Required Conditions relating to a Virtual Tape Server in the Library (continued)

Intervention Required Condition

Resolution Actions

 

 

 

 

Message

1. Contact your service representative.

 

 

 

VTS Physical device xxx is cabled incorrectly. It has

 

 

been made unavailable. (VTS z)

 

 

Probable Cause

 

 

During the installation of drive xxx, the interface cables

 

 

between the drive and the library manager were

 

 

incorrectly installed.

 

 

 

 

 

Message

1. Contact your service representative.

 

 

 

A VTS cannot communicate with device xxx. It has

 

 

been made unavailable. (VTS z)

 

 

Probable Cause

 

 

Drive xxx has either been powered-off or has a failure

 

 

that does not allow it to respond to requests from the

 

 

VTS.

 

 

 

 

 

Message

1. Refer to ªUsing the Search Database for Volumes

 

 

 

Mount of logical volume xxxxxx failed because

Windowº on page 279, and follow the instructions in

 

the ªSpeci®c Misplaced Volumeº scenario using the

 

physical volume yyyyyy is misplaced. (rc=rrrr) (VTS z)

 

physical volume volser for your search.

 

 

 

Probable Cause

 

 

To satisfy a logical volume mount request, the logical

 

 

volume must be recalled from a physical volume. The

 

 

mount of the physical volume failed because it was not

 

 

found in the physical storage cell indicated in the library

 

 

manager inventory.

 

 

 

 

 

Message

1. Refer to ªUsing the Search Database for Volumes

 

 

 

Mount of logical volume xxxxxx failed because

Windowº on page 279, and follow the instructions in

 

the ªSpeci®c Inaccessible Volumeº scenario using the

physical volume yyyyyy is inaccessible. (rc=rrrr) (VTS

physical volume volser for your search.

z)

 

 

Probable Cause

 

 

To satisfy a logical volume mount request, the logical

 

 

volume must be recalled from a physical volume. The

 

 

mount of the physical volume failed because it is not

 

 

accessible by the robotics of the library. The two most

 

 

likely reasons for the volume to be inaccessible are that

 

 

the volume is loaded in a drive that has failed or is in a

 

 

gripper that has failed.

 

 

 

 

 

300Magstar 3494 Tape Library Operator Guide

Page 322
Image 322
IBM Magstar 3494 manual Mount of logical volume xxxxxx failed because, Physical volume yyyyyy is misplaced. rc=rrrr VTS z