Table for Intervention Conditions of External Cartridge Labels

Table 19. Intervention Required Conditions relating to external cartridge labels

Intervention Required Condition

Resolution Actions

 

 

 

Message

1.

Remove the cartridge from the convenience I/O

 

A duplicate volser (xxxxxx) was ejected to the

 

station.

 

 

convenience I/O station.

2.

Determine why the cartridge is a duplicate and take

Probable Cause

 

corrective action.

 

 

During an inventory or inventory update operation, a

 

 

cartridge was found whose external volume serial

 

 

number, xxxxxx, is the same as that of another cartridge

 

 

in the library. The volume was placed in the convenience

 

 

I/O station. The library does not support more than one

 

 

cartridge with the same volume serial number.

 

 

 

 

 

Message

1.

Place the library system in pause mode.

 

A duplicate volser (xxxxxx) was ejected to

2.

Open the appropriate enclosure door.

 

 

high-capacity facility cell: yyyy.

3.

Remove the cartridge from the high-capacity facility.

Probable Cause

4.

Determine why the cartridge is a duplicate and take

 

corrective action.

 

 

During an inventory or inventory update operation, a

5.

Close the enclosure door.

cartridge was found whose external volume serial

6.

Place the library system in auto mode.

number, xxxxxx, is the same as that of another cartridge

 

 

in the library. The convenience I/O station is either not

 

 

installed, is full or is unavailable. The volume was placed

 

 

in high-capacity facility cell, yyyy. The library does not

 

 

support more than one cartridge with the same volume

 

 

serial number.

 

 

 

 

 

Message

1.

Remove the cartridge from the convenience I/O

 

A duplicate volser (xxxxxx) was left in the

 

station.

2.

Determine why the cartridge is a duplicate and take

convenience I/O station.

 

corrective action.

 

 

Probable Cause

 

 

During an insert operation, a cartridge was found whose

 

 

external volume serial number, xxxxxx, is the same as

 

 

that of another cartridge in the library. The library does

 

 

not support more than one cartridge with the same

 

 

volume serial number.

 

 

 

 

 

Message

1.

Place the library system in pause mode.

 

A duplicate volser (xxxxxx) was left in high-capacity

2.

Open the appropriate enclosure door.

 

 

facility cell: yyyy.

3.

Remove the cartridge from the high-capacity facility.

Probable Cause

4.

Determine why the cartridge is a duplicate and take

 

corrective action.

 

 

During an insert operation, a cartridge was found in

5.

Close the enclosure door.

high-capacity facility cell, yyyy, whose external volume

6.

Place the library system in auto mode.

serial number, xxxxxx, is the same as that of another

 

 

cartridge in the library. The library does not support more

 

 

than one cartridge with the same volume serial number.

 

 

 

 

 

288Magstar 3494 Tape Library Operator Guide

Page 310
Image 310
IBM Magstar 3494 manual Duplicate volser xxxxxx was ejected to, Duplicate volser xxxxxx was left, Facility cell yyyy