Cartridge Removal from the Gripper

Some operator intervention conditions require the operator to remove the cartridge from the gripper. Figure 149 shows the picker and the gripper assembly. Remove the cartridge from the gripper by doing the following:

1.Press the Pause button on the operator control panel if the library is not already in Pause mode.

2.Open the front door on the library in front of the cartridge accessor.

3.Rotate the picker „1… so the picker is pointing toward the right side of the machine, paralleling the rails „3….

4.Push the reach assembly „5… out so it is fully extended.

5.Press the top „2… of the gripper assembly to release the cartridge „4….

6.Push the reach assembly in so it is fully retracted.

7.Close the front door.

8.Press the Auto button on the operator control panel to return the library to Auto mode.

A06C0114

Figure 149. Cartridge Removal from the Gripper

Chapter 6. Advanced Operating Procedures 239