ÐThis indicates that the parameter is not used for this Library Manager OPINT messages.

Gripper

Valid Gripper values are: 1, which indicates gripper one; and 2, which indicates gripper two.

Accessor

Valid Accessor values are: A, which indicates accessor A; and B, which indicates accessor B.

Note: Only High Availability 3494s have an accessor B.

Device

Valid Device values will be from 0 to 0xFFF. This parameter will always be reported in hexadecimal.

Volser This will be a six character string (example: CNN444).

Rack Cell

The Rack Cell parameter has the following format: RackColumnCell. As an

example: 1G1 means rack 1, column G and cell 1.

External

Same as Volser - Only used in libraries with VTSs.

Internal

Same as Volser - Only used in libraries with VTSs.

VTS Valid VTS parameters are:

vVTS_1, which indicates VTS 1

vVTS_2, which indicates VTS 2

Certain versions of OS/2 trap if the overall SNMP message is over 132 bytes in length. To prevent this trap, the Library Manager software checks to see if the SNMP trap message is longer than 132 bytes, and inserts a NULL character at the 132 byte limit. Therefore, some Library Manager OPINT SNMP traps will be truncated to prevent this problem.

Table 7 contains the Library Manager OPINT interventions.

Table 7. Operator Intervention Messages and Parameters (OPINT TRAP Type)

 

Parameter

Parameter

Parameter

Actual Library Manager OPINT Trap

OPINT #

[A]

[B]

[C]

Message

 

 

 

 

 

1

Gripper

Accessor

Ð

Gripper Failure on gripper [A], accessor [B]

 

 

 

 

 

2

Device

Ð

Ð

Index failure on device [A]

 

 

 

 

 

3

Ð

Ð

Ð

*The convenience I/O station is full.

 

 

 

 

 

4

Ð

Ð

Ð

*The library is full.

 

 

 

 

 

5

Volser

Ð

Ð

A duplicate volser ( [A]) was ejected to the

 

 

 

 

convenience I/O station.

 

 

 

 

 

6

Volser

Ð

Ð

A duplicate volser ( [A]) was left in the

 

 

 

 

convenience I/O station

 

 

 

 

 

7

Ð

Ð

Ð

An unreadable volser was left in the

 

 

 

 

convenience I/O station

 

 

 

 

 

8

Ð

Ð

Ð

*The library is out of CST/ECCST cleaner

 

 

 

 

cartridges.

 

 

 

 

 

216Magstar 3494 Tape Library Operator Guide

Page 238
Image 238
IBM Magstar 3494 manual Rack Cell, External, Internal, Parameter Actual Library Manager Opint Trap