Table 12. DFSMS Messages Based on Library Failure or Exception Conditions (continued)

Resulting Console Message

Action

 

 

CBR3755E {InputOutput} door open in library

Go to the library and close the station door. There is also

library-name.

an intervention-required condition set for this condition. It

One of the following situations has been detected in

is automatically cleared when the station door is closed.

 

library library-name:

 

v The station door has been open for more than 5

 

minutes.

 

v An eject operation cannot be completed because the

 

door is open.

 

This message is retained on the console until the open

 

door has been closed.

 

 

 

CBR3757E Library library-namein {paused/manual

1. The library may no longer be in auto mode because

mode} operational state.

of an operational requirement such as high-capacity

 

Library library-nameis not running in auto (normal) mode.

I/O or service.

2. If no operation or service was planned for the library

The operational state (mode) is one of the following:

that would have caused the change in mode, go to

Paused

the library and determine why it is no longer in auto

All mechanical motion in the library has stopped.

mode.

Paused mode is entered automatically when a

3. If there are intervention-required conditions at the

failure in the library prevents further automated

library, perform them and then return the library to

operation, or entered by a command from the

auto mode.

library manager operator console. The library

4. If a repair action is required, contact your service

manager continues to accept orders from the

representative.

host, but queues them for execution after pause

 

mode changes to auto or manual mode.

 

Manual mode

 

All mechanical motion within the library has

 

stopped. Manual mode is entered by command

 

from the library manager operator console. The

 

library manager continues to accept orders from

 

the host and instructs the operator to manually

 

perform the functions that are normally done

 

automatically, such as volume fetch and

 

mounting.

 

This message is retained on the console until the library

 

has returned to the automated operational state.

 

 

 

CBR3758E Library library-nameoperation degraded.

1. Contact your service representative.

 

One or more components of library library-namehave

2. There also may be one or more intervention-required

conditions at the library to perform.

failed or otherwise become unavailable for use. The

 

library is continuing to function, but performance may be

 

degraded. If this message is accompanied by the

 

CBR3760E Library library-namevision system not

 

operational message, audit and eject requests cannot be

 

performed and volumes cannot be added to the library.

 

This message is retained on the console until all library

 

facilities have become fully operational.

 

 

 

272Magstar 3494 Tape Library Operator Guide

Page 294
Image 294
IBM Magstar 3494 CBR3757E Library library-namein paused/manual, Mode operational state, Paused, Manual mode