Operational State Change SNMP Traps

The Operational State Change message format is as follows:

3494 [Library Sequence Number] UNSOL 13 [Mode] [State] [Degraded] [Safety Enclosure Interlock Open] [Vision System Non-Operational] [Intervention Required] [Check1] [Storage Cells Full] [Out of Cleaners] [Dual Write Disabled] [Smoke Detected] [Manual Mode] *Operational State Change

Library Sequence Number

Unique Library Sequence Number of the 3494 Tape Dataserver that generated the SNMP trap message.

Mode It will be one of the following:

vAUTO

vPAUSE

vMANUAL

State It will be one of the following:

vONLINE

vOFFLINE

Degraded

It will be one of the following:

vÐ

vDEGRAD

Safety Enclosure Interlock Open

It will be one of the following:

vÐ

vSO

Vision System Non-Operational

It will be one of the following:

vÐ

vVN

Intervention Required

It will be one of the following:

vÐ

vIR

Check1

It will be one of the following:

vÐ

vC1

All Storage Cells Full

It will be one of the following:

vÐ

vSF

Out of Cleaners

It will be one of the following:

vÐ

vOC

Chapter 6. Advanced Operating Procedures 223

Page 245
Image 245