MultiVOIP User Guide

 

 

Technical Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E1 Parameter Definitions (cont’d)

 

Field Name

 

Values

Description

 

 

General E1/E1/ISDN Parameters

 

 

 

 

 

 

 

 

 

Line Build Out

 

0 dB, -7.5 dB,

To reduce the crosstalk on

 

 

 

 

-15 dB, -22.5 dB

received signals, a transmit

 

 

 

 

 

attenuator can be placed in the

 

 

 

 

 

data path. Transmit attenuation

 

 

 

 

 

is selectable. Default: O dB

 

 

 

 

 

 

 

 

Pulse Shape

 

0 to 40 Meters

Refers to length of cable

 

Level

 

40 to 81 m

between MultiVOIP and

 

 

 

 

81 to 122 m

PBX/telco in meters. Most

 

 

 

 

122 to 162 m

common will be 0 to 40m.

 

 

 

 

162 to 200 m

 

 

 

 

 

 

 

 

Caller ID Parameters

 

 

 

Caller ID

 

Y/N

Turns Caller ID feature on (if

 

 

Enable

 

 

checked) and off (if unchecked).

 

 

 

 

 

 

 

 

Calling

 

0-9, *, #

A DTMF symbol used to mark the

 

 

Number Prefix

 

 

beginning of the calling party

 

 

(Caller ID)

 

 

number for use with Caller ID.

 

 

 

 

 

Maximum length: 4 characters.

 

 

 

 

 

 

 

 

Calling

 

0-9, *, #

A DTMF symbol used to mark

 

 

Number Suffix

 

 

the end of the calling party

 

 

(Caller ID)

 

 

number for use with Caller ID.

 

 

 

 

 

Maximum length: 4 characters.

 

 

 

 

 

 

 

 

Detect Flash

 

Y/N

This setting determines whether

 

 

Hook

 

 

or not the MultiVOIP responds

 

 

 

 

 

to hook-flash signals.

 

 

 

 

 

 

 

 

Detection Time

 

100 – 1500

Minimum hook-flash time that

 

 

 

 

milliseconds

will be interpreted as a valid

 

 

 

 

 

flash by the MultiVOIP.

 

 

 

 

 

 

 

 

Generation

 

100 – 1500

In some systems, a MultiVOIP

 

 

Time

 

milliseconds

might receive a hook-flash signal

 

 

 

 

 

from an upstream device (a PBX,

 

 

 

 

 

voip or other device) and must

 

 

 

 

 

replicate it to a downstream device.

 

 

 

 

 

This parameter determines the

 

 

 

 

 

duration of the hook-flash signal

 

 

 

 

 

that is passed to a downstream

 

 

 

 

 

device.

 

 

 

 

 

 

 

 

Clocking

 

External/Internal

Set opposite to telco/PBX

 

 

 

 

 

setting. Example: if telco

 

 

 

 

 

clocking internal, set VOIP

 

 

 

 

 

clocking as external.

 