Technical Configuration |
| MultiVOIP User Guide | ||
|
|
|
|
|
|
|
|
|
|
| Custom |
| ||
|
|
|
|
|
| Field Name | Values | Description |
|
|
|
|
|
|
| Cadence 1 | integer time | On/off pattern of tone durations |
|
|
| value in | used to denote phone ringing, |
|
|
| phone busy, dial tone (“0” |
| |
|
| zero value for | indicates continuous tone) |
|
|
| survivability and |
| |
|
| indicates | Cadence 1 is duration of first |
|
|
| continuous tone | period of tone being “on” in the |
|
|
|
| cadence of the telephony signal |
|
|
|
| (which could be |
|
|
|
| tone, |
|
|
|
| tone). |
|
|
|
|
|
|
| Cadence 2 | duration in | Cadence 2 is duration of first |
|
|
| milliseconds | “off” period in signaling |
|
|
|
| cadence. |
|
|
|
|
|
|
| Cadence 3 | duration in | Cadence 3 is duration of second |
|
|
| milliseconds | “on” period in signaling cadence. |
|
|
|
|
|
|
| Cadence 4 | duration in | Cadence 4 is duration of second | |
|
| milliseconds | “off” period in the signaling |
|
|
|
| cadence, after which the |
|
|
|
| cadence pattern of the telephony |
|
|
|
| signal repeats. |
|