MultiVOIP User Guide

 

 

 

 

 

 

 

 

 

 

 

 

T1 Statistics: Field Definitions (cont’d)

 

 

 

 

 

 

 

Field

Values

Description

 

 

Name

 

 

 

 

 

 

 

 

 

Yellow

Tally since last

The alarm signal sent by a remote T1/E1

 

 

Alarm

reset.

device to indicate that it sees no receive

 

 

 

 

signal or cannot synchronize on the

 

 

 

 

receive signal.

 

 

 

 

 

 

 

Frame

 

[To be supplied.]

 

 

Search

 

 

 

 

Restart Flag

 

 

 

 

 

 

 

 

 

Loss of

Tally since last

In D4 or ESF mode, displayed value will

 

 

MultiFrame

reset.

increment if multiframe alignment has

 

 

Alignment

 

been lost or if loss of frame alignment has

 

 

 

 

been detected.

 

 

 

 

 

 

 

Transmit

Tally since last

Slip in transmitted data stream. Slips

 

 

Slip

reset.

indicate a clocking mismatch (or lack of

 

 

 

 

synchronization) between T1/E1 devices.

 

 

 

 

When slips occur, data may be lost or

 

 

 

 

repeated.

 

 

 

 

 

 

 

Pulse

 

The pulse density of the received data

 

 

Density

 

stream is below the requirement defined

 

 

Violation

 

by ANSI T1.403 or more than 15

 

 

 

 

consecutive zeros are detected.

 

 

 

 

 

 

 

Line

 

The line loopback activation signal

 

Loopback

 

has been detected in the received bit

 

 

Activation

 

stream.

 

 

Signal

 

 

 

 

 

 

 

 

 

Transmit

 

At least 32 consecutive zeros were

 

Line Open

 

transmitted.

 

 

 

 

 

 

 

Transmit

 

For use by MTS Technical Support

 

Data

 

Personnel.

 

 

Underrun

 

 

 

 

 

 

 

 

 

Transmit

 

The frequency of the transmit clock is

 

Slip

 

greater than the frequency of the

 

 

Negative

 

transmit system interface working

 

 

 

 

clock. A frame is skipped.

 

 

 

 

 

 

282