Chapter 4 – Configuring Your MultiVOIP

Configuring FXS Loop Start Parameters

The figure and table that follow describe the parameters applicable to FXS Loop Start.

FXS Loop Start Interface: Parameter Definitions

Field Name

Values

Description

 

 

 

Dialing Options fields

 

 

 

 

FXS (Loop Start)

Y/N

Enables FXS Loop Start interface type.

 

 

 

Inter Digit Timer

1 ‐ 10 seconds

This is the length of time that the MultiVOIP waits between digits. When the

 

 

time expires, the MultiVOIP looks in the outbound phonebook for the number

 

 

entered and place the call accordingly.

 

 

Default = 2.

 

 

 

Message Waiting Indication

‐‐

Not applicable to –SS series MultiVOIPs.

 

 

 

Inter Digit Regeneration

in milliseconds

The length of time between the outputting of DTMF digits.

Time

 

Default = 100 ms.

 

 

 

FXS Options fields

 

 

 

 

FXS Ring Count, FXS

1‐10

Maximum number of rings that the MultiVOIP issues before giving up the

 

 

attempted call.

 

 

 

Current Loss

Y/N

When enabled, the MultiVOIP interrupts loop current in the FXS circuit to

 

 

initiate a disconnection. This tells the device connected to the FXS port to hang

 

 

up. The Multi‐VOIP cannot drop the call; the FXS device must go on hook.

 

 

 

Generate Current Reversal

Y/N

When selected, this option implements Answer Supervision and Disconnect

 

 

Supervision to the FXO interface using current reversal to indicate events.

 

 

Applicable only when FXS and FXO interfaces are connected back to back.

 

 

 

Table is continued on next page…

 

MultiVOIP® Voice/Fax over IP Gateways

45

Page 45
Image 45
Multitech MVP210 Configuring FXS Loop Start Parameters, FXS Loop Start Interface Parameter Definitions, FXS Options fields