6.4.4 Fan(s) Not Working / Overheating

This equipment has forced air cooling and must not be operated unless all cooling fans are working. In the event of overheating problems, refer to table.

Note: Failure to ensure a free air flow around the unit may cause overheating.

Step

Action

If the result of action is Yes...

If the result of action is

 

 

 

No...

1

Check Fan

Check that the Video Gateway

 

Rotation.

has been installed with sufficient

 

Inspect the fans

space allowed enclosure for air

 

located at the

flow. If the air is too hot,

 

sides of the unit.

additional cooling may be

 

Are the fans

required.

 

rotating?

 

Possible break in the dc supply from the PSU module to the suspect fan(s). Call a Service Engineer.

6.4.5 Alarm LED lit / Alarm condition

The alarm LED on front and rear will light when a critical alarm occurs.

The following table describes the different alarm conditions and what might be the cause of these alarms.