ASI-IP-GTW User's Manual

Table 12. Alarms

Alarm

Alarm

Severity level

Description

id

 

 

 

100

No sync

Critical

No valid ASI input stream detected.

 

 

 

 

101

ASI bitrate too high

Critical

The ASI input bitrate has exceeded the

 

 

 

configured maximum value.

121

Bitrate regulation in Filtered

 

progress

The regulation algorithm is estimating the incoming bitrate to compensate for the difference in PCR clocks on the source encoder and the IP receiver. While this alarm is active, the output bitrate may be tuned beyond the limits of the ASI specifications.

130

Ethernet link down

Critical

No link on Ethernet layer

131

Output buffer

Warning

The total bitrate of the ASI input streams is

 

overflow

 

too high.

 

 

 

 

140

ARP unresolved

Warning

IP address is not resolved into physical

 

 

 

MAC address.

 

 

 

 

150

Sequence error

Warning

Analysis of the sequence number of the

 

 

 

RTP layer indicates that IP frames have

 

 

 

been lost or that they have been received

 

 

 

out of order.

 

 

 

 

151

No data received

Warning

No data received on Ethernet input for

 

 

 

stream

 

 

 

 

152

FEC threshold

Warning

The frequency of lost frames is higher than

 

exceeded

 

the configured value. Threshold values are

 

 

 

configured per stream.

 

 

 

 

153

Input buffer

Warning

The total bitrate of the IP input streams is

 

overflow

 

too high.

 

 

 

 

154

Data lost

Critical

The data stream received for a channel is

 

 

 

incomplete, and if running FEC, the FEC

 

 

 

engine is not able to recover all the lost

 

 

 

frames.

 

 

 

 

155

No lock

Critical

The IP receive channel is not able to find

 

 

 

an initial bitrate for the data received.

156

MIP not present

Warning

No MIP frames are received.

 

 

 

 

157

Too low latency for

Warning

The preferred latency is set lower than the

 

FEC

 

latency required by the incoming stream.

 

 

 

 

160

SNTP server

Warning

Unit is not receiving answers from the

 

unreachable

 

SNTP server.

161

Too high

Warning

Internal temperature of unit is too high.

 

temperature

 

 

 

 

 

 

162

Defective fan

Warning

One or both of the fans are not spinning.

 

 

 

 

200

No GPS 1PPS

Warning

The 1PPS reference signal is lost. (The

 

reference signal

 

regulator has however not lost

 

 

 

synchronization)

 

 

 

 

201

Lost GPS 1PPS

Critical

The clock synchronization mechanism has

 

synchronization

 

been resynchronized due to too large

 

 

 

phase error.

 

 

 

 

Page 66

Page 66
Image 66
Network Technologies DVB-ASI to IP, ASI-IP-GTW user manual Alarm Severity level Description