Omega Vehicle Security OM-550 manual POWER/CURRENT Requirements, Battery Life, Physical Dimensions

Models: OM-550

1 84
Download 84 pages 19.9 Kb
Page 56
Image 56

POLLUTION DEGREE:

Pollution Degree 2 per IEC Publication

 

664

This classification means that normally only non-conductive pollution (in the form of dust) occurs. Occasionally, however, a temporary conductivity caused by condensation must be expected.

INSTALLATION CATEGORY

(OVERVOLTAGE CATEGORY):Installation Category II per IEC publication 664

This classification applies to products used on electric supply branch circuits. This is defined as a classification of parts of installation systems or circuits with standardized limits for transient overvoltages, dependent on the nominal line voltage to earth.

POWER/CURRENT REQUIREMENTS

 

INTERNAL CELLS:

4-AA alkaline cells

OM-550 POWER INPUT:

9VDC, 50 mA (700 mA Peak while

 

printing)

AC POWER ADAPTER

 

INPUT:

120 VAC or 230 VAC, model-specific

OUTPUT:

9 VDC, 1 A, 9 W

EXTERNAL OPTIONAL BATTERY PACK:

12 VDC, Rechargeable,

FUSE FOR DC POWER CABLE:

2A/250V, 0.25" x 1.25" (6.3 mm x 32 mm)

BATTERY LIFE

 

INTERNAL CELLS:

Approximately 8000 printed lines

PHYSICAL DIMENSIONS

4" W X 9.5" D X 1.5" H (with paper roll)

WEIGHT:

2 lb. (with batteries and paper)

CALIBRATION:

NIST traceability

RECALIBRATION PERIOD:

6 months

WARRANTY PERIOD:

1 year

SHIPPING WEIGHT:

6 Lb.

CONNECTORS

 

ANALOG INPUTS:

Miniature female thermocouple style

DC POWER:

5.5 mm X 2.1 mm (.216" X .080") male

 

jack

RS-232 DATA PORT:

4 Position 4 Circuit Modular (4P4C)

OM-550

u51u

Page 56
Image 56
Omega Vehicle Security OM-550 manual POWER/CURRENT Requirements, Battery Life, Physical Dimensions, Connectors