Warning System

Warning Description Tables

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING lamp, lamps inside the viewfinder and a warning tone.

‹Note

The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors occur simultaneously a higher priority indication will be triggered. The [9. Low Wireless Signal Reception], however, may not be indicated, depending on the menu setting.

1. System Errors

Display window

The error code lights up.

indication

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second.

 

 

Viewfinder

The SYSTEM ERROR indication and the error

code light up.

 

 

 

Warning tone

Beeps continuously.

 

 

Warning

An error in the reference signal or the

description

communication.

 

 

Recording/

 

playback

The operation stops.

operation

 

 

 

Countermeasures

Please confirm [Error Codes] (page 155) and

 

consult your distributor.

2. Card removal error

Display window

Error code E-30 blinks.

indication

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

Tally lamp

Blinks 4 times per second.

 

 

Viewfinder

The “TURN POWER OFF” indicator lights up.

 

 

Warning tone

Continues to beep.

 

 

Warning

The P2 card being accessed has been

removed, resulting in an error in the internal

description

memory of the camera-recorder.

 

 

 

Recording/

 

playback

Cannot be performed.

operation

 

 

 

 

Turn off the power to the camera-recorder. If

Countermeasures

there is an error in a clip on the removed P2

 

card, repair the clip.

 

 

3. Battery Empty

Display window

All 7 bar indicators for battery remaining

 

 

indication

capacity start blinking.

 

 

 

 

 

 

 

WARNING lamp

Lights up.

 

Maintenance

 

 

 

Warning tone

Beeps continuously.

 

Tally lamp

Blinks once per second.

 

 

Viewfinder

The BATT LED lights up.

 

 

 

 

 

and

Warning

The battery has run out.

 

 

 

description

 

Inspections

 

 

 

 

 

Recording/

 

 

 

 

 

playback

The operation stops.

 

 

operation

 

 

 

 

 

 

 

Countermeasures

Replace the battery.

 

 

 

 

 

 

4. P2 Card Fully Recorded

 

 

 

 

Display window

All 7 bar indicators for remaining MEDIA

 

 

indication

capacity start blinking.

 

 

 

 

 

 

WARNING lamp

This lamp will illuminate continuously until an

 

 

operation is made after recording.

 

 

 

 

 

 

 

 

 

Tally lamp

This lamp will flash 4 times every second until

 

 

an operation is made after recording.

 

 

 

 

 

 

 

 

 

Viewfinder

The END indicator blinks.

 

 

 

 

 

 

Warning tone

This tone will sound continuously until an

 

 

operation is made after recording.

 

 

 

 

 

 

 

 

 

Warning

The P2 cards are recorded to maximum

 

 

description

capacity.

 

 

 

 

 

 

Recording/

 

 

 

playback

The recording stops.

 

 

operation

 

 

 

 

 

 

 

Countermeasures

Delete the clips in the P2 card or insert a new

 

 

 

P2 card.

 

 

Maintenance and Inspections: Warning System 153