Card Warning Code

Code No.

Description

Recording

Indication in display

window

 

 

 

 

 

 

 

 

 

 

 

 

The directory structure on the P2 card is not

Operation continues. However, back up data

 

E-70

supported. ([DIR NG CARD (Slot No.)] is

on the P2 card as soon as possible, and format

A warning code blinks once

 

indicated on the viewfinder.)

the card before using it again.

every 2 seconds on the time

 

The maximum number of overwrites on the P2

Operation continues. However, recording or

 

code display section of the

 

card has been exceeded. ([RUN DOWN CARD

playback may not operate correctly. It is

E-71

display window.

(Slot No.)] is indicated on the viewfinder.)

recommended that you replace the P2 card

 

 

 

 

with another one.

 

 

 

 

 

Warning and Error Display for Thumbnail Operation and USB HOST MODE

Item

Message

 

Description

Measure

 

 

 

 

 

CANNOT ACCESS!

Data cannot be accessed because it is

Restore media and clips to normal state before

 

 

corrupted or for other reasons.

access.

 

 

 

 

 

CANNOT CHANGE!

With the AVC-Intra100 or AVC-Intra50, clips

Please set the SYSTEM MODE item to match the

 

 

for which thumbnails cannot be created, and

clip. The menu item SYSTEM MODE is found in the

 

 

for which the

mark is displayed cannot

<SYSTEM MODE> screen on the SYSTEM

 

 

have the thumbnail for their text memo

SETTING page.

 

 

position changed.

 

 

 

 

 

 

CANNOT COPY!

Images cannot be copied.

Check the conditions for copying.

 

 

 

 

 

CANNOT DELETE !

Contents version mismatch prevents deletion.

Match devices and contents version.

 

 

 

 

 

CANNOT FORMAT!

P2 card problem prevents formatting.

Check P2 card.

 

 

 

 

 

CANNOT RE-

A clip that does not span multiple cannot be

Check selected content.

 

CONNECT!

reconnected.

 

 

 

 

 

 

 

 

 

CANNOT REPAIR!

Data cannot be repaired since content that

Check selected content.

 

 

cannot be repaired is selected.

 

 

 

 

 

 

 

 

LACK OF REC

There is not enough recording capacity left on

Insert a card with sufficient recording capacity.

 

CAPACITY!

the card.

 

 

 

 

 

 

 

MISSING CLIP!

A shot mark will be added to the clips recorded

Insert all P2 cards with recorded clips, and confirm

 

 

on multiple P2 cards when all P2 cards are not

that the incomplete clip indicators disappear, and

Thumbnails

 

inserted yet.

 

then add shot marks.

 

 

 

 

NO CARD!

No P2 or SD card is inserted.

Insert compatible media.

 

 

 

 

 

 

NO COPY TO SAME

A clip cannot be copied to the card storing the

Copy the selected clip to a card that does not

 

CARD!

original clip.

 

contain the original clip.

 

 

 

 

 

NO FILE!

The designated file is not found.

Check the file.

 

 

 

 

 

 

SAME CLIP IS

Images cannot be copied since the clip has

Confirm the selected clip and release either the

 

SELECTED!

source clip or the destination clip and then execute

 

already been copied from the original clip.

 

 

the copy operation.

 

 

 

 

 

 

 

 

 

TOO MANY CLIPS!

Too many clips are selected.

Reduce the number of selected clips.

 

 

 

 

 

 

UNKNOWN

Warning displayed to indicate contents version

 

 

CONTENTS

Match devices and contents version.

 

FORMAT!

mismatch.

 

 

 

 

 

 

 

 

 

 

 

 

UNKNOWN DATA!

The metadata character code is invalid.

Use UTF-8 for the metadata character code. Use

 

 

the viewer to enter correct characters.

 

 

 

 

 

 

 

 

 

USER CLIP NAME

Characters in the clip name had to be deleted

The user clip name plus the counter value can only

 

MODIFIED!

in adding the counter value.

contain up to 100 bytes. Characters in the clip name

 

 

 

 

are automatically deleted when the total exceeds

 

 

 

 

100 bytes.

 

 

 

 

 

WRITE

The P2 or SD card is write protected.

Insert write-enabled media.

 

PROTECTED!

 

 

 

 

 

 

 

 

CANNOT CHANGE!

[PERSON] will be entered while the text

Enter [TEXT] before entering [PERSON].

Soft

 

memo is not available.

 

keyboard

 

 

 

CANNOT SET!

The entered value is incorrect.

Change the value.

 

INVALID VALUE!

 

 

 

 

 

 

 

 

156 Maintenance and Inspections: Warning System