REC FUNCTION

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

INTERVAL

OFF

Sets INTERVAL REC function.

REC MODE

ON

OFF: INTERVAL REC is not performed.

 

 

 

 

 

ONE SHOT

ON: Uses internal memory to perform

 

 

 

 

 

 

interval recording.

 

 

 

 

 

 

ONE SHOT:

 

 

 

 

 

 

Performs “one-shot” recording for the

 

 

 

 

 

 

duration specified under REC TIME,

 

 

 

 

 

 

and then stops.

 

 

 

 

 

 

‹Note

 

 

 

 

 

 

This item cannot be changed when “ON”

 

 

 

 

 

 

is selected for the LOOP REC MODE

 

 

 

 

 

 

item or for the ONE CLIP REC MODE

 

 

 

 

 

 

item.

 

 

 

 

 

 

In addition, this does not work in Native

C

U

F

 

mode or in 24P and 24PA modes.

 

 

 

 

 

 

 

INTERVAL

ON

Selects whether INTERVAL REC MODE

REC HOLD

OFF

settings are retained or not when the

 

 

 

 

 

 

power is turned off once.

 

 

 

 

 

 

ON: Retain

 

 

 

 

 

 

OFF: Do not retain. The INTERVAL REC

 

 

 

 

 

 

MODE is OFF whenever the power

C

U

F

 

is turned on again.

 

 

 

 

 

 

 

REC TIME *

00s01f

Set REC TIME (1 cut).

 

 

 

 

 

:

‹Note

 

 

 

 

 

59s29f

However, the settings can be made frame

 

 

 

 

 

 

by frame, and the numbers of the cut-off

 

 

 

 

 

 

unit frames for the shortest time period

 

 

 

 

 

 

and the set time on the actual operation

 

 

 

 

 

 

may vary with the recording method. For

 

 

 

 

 

 

details, refer to [Interval Recording] (page

 

 

 

 

 

39).

C

U

F

 

 

 

 

 

 

 

 

PAUSE TIME *

00h00m00s01f

Specify PAUSE time for recording.

 

 

 

 

 

:

‹Note

 

 

 

 

 

00h04m59s29f

However the settings can be made frame

 

 

 

 

 

:

by frame, and the numbers of the cut-off

 

 

 

 

 

23h59m59s29f

unit frames for the shortest time period

 

 

 

 

 

 

and the set time on the actual operation

 

 

 

 

 

 

may vary with the recording method. For

 

 

 

 

 

 

details, refer to [Interval Recording] (page

 

 

 

 

 

39).

C

U

F

 

 

 

 

 

 

 

 

TAKE TOTAL

NONE

Specify the time needed for shooting.

TIME

:

Select from NONE (continue until

C

U

F

5day

operation is manually stopped) to 5 days.

 

 

 

 

 

 

 

TOTAL REC

00m00s01f

Display total recorded time. The setting

TIME *

:

cannot be changed using this option.

 

 

 

 

 

99m59s29f

Displays the recording time (recording

 

 

 

 

 

OVER100min

time needed for the P2 card) calculated

 

 

 

 

 

NONE

using REC TIME, PAUSE TIME, and

 

 

 

 

 

 

TAKE TOTAL TIME.

 

 

 

 

 

 

‹Note

 

 

 

 

 

 

A value based on actual processing is

 

displayed.

START DELAY

0SEC

Set the delay after pressing REC button

 

 

 

 

 

:

to start recording in INTERVAL REC.

 

 

 

 

 

10SEC

 

C

U

F

 

 

 

 

 

 

 

 

PRE REC

ON

Select whether or not to enable PRE-

MODE

OFF

RECORDING.

 

 

 

 

 

 

ON: PRE-RECORDING enabled.

 

 

 

 

 

 

OFF: PRE-RECORDING disabled.

 

 

 

 

 

 

‹Note

 

 

 

 

 

 

Specify the PRE-RECORDING time by

 

 

 

 

 

 

using the menu option PRE REC TIME.

C

U

F

 

 

 

 

 

 

 

 

 

 

*This variable range is the numerical values for 59.94 Hz. For 50 Hz, the frame rate is up to 24f.

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

PRE REC

1SEC

Set PRE RECORDING.

TIME

:

1-15SEC:

 

 

 

 

 

8SEC

Set the length of time that can be

 

 

 

 

 

:

retrospectively recorded before the

 

 

 

 

 

15SEC

REC button is pressed.

 

 

 

 

 

 

‹Note

 

 

 

 

 

 

When the SYSTEM MODE menu option

 

 

 

 

 

 

on the SYSTEM MODE screen is set to

 

 

 

 

 

 

1080-59.94i or 1080-50i, or when it is set

 

 

 

 

 

 

to 480-59.94i or 576-50i and the REC

 

 

 

 

 

 

MODE menu option is set to DVCPRO50,

 

 

 

 

 

 

the upper limit of the above recording

 

 

 

 

 

 

time is 8 seconds.

C

U

F

 

 

 

 

 

 

 

 

 

 

LOOP REC

ON

Select whether or not to enable LOOP REC.

MODE

OFF

This setting can be used with PRE-

 

 

 

 

 

 

RECORDING features.

 

 

 

 

 

 

ON: Enable LOOP REC.

 

 

 

 

 

 

OFF: Disable LOOP REC.

 

 

 

 

 

 

‹Notes

 

 

 

 

 

 

z After the power is turned off, this item

 

 

 

 

 

 

will default to OFF the next time the

 

 

 

 

 

 

power is turned on.

 

 

 

 

 

 

z This item cannot be changed in the

 

 

 

 

 

 

following cases.

 

 

 

 

 

 

ŠWhen “ON” or “ONE SHOT” is

 

 

 

 

 

 

selected for the INTERVAL REC

 

 

 

 

 

 

MODE item

 

 

 

 

 

 

ŠWhen “ON” is selected for the ONE

 

 

 

 

 

 

CLIP REC MODE item

 

 

 

 

 

 

z This does not work in Native mode or

 

 

 

 

 

 

in 24P and 24PA modes.

F

 

 

 

 

 

 

 

 

 

 

REC START

ALL

Select operating modes that allow

 

 

 

 

 

NORMAL

recording to start.

 

 

 

 

 

 

ALL: Allow recording to start during stop,

 

 

 

 

 

 

recording pause, and playback.

 

 

 

 

 

 

NORMAL:

 

 

 

 

 

 

Allow recording to start during stop

 

 

 

 

 

 

and recording pause.

 

 

 

 

 

 

‹Note

 

 

 

 

 

 

Even if this is set to “ALL”, the operation

 

 

 

 

 

 

is “NORMAL”, when “ON” or “ONE

 

 

 

 

 

 

SHOT” is selected in INTERVAL REC

C

U

F

 

 

MODE.

P.ON REC

HOLD

Select the recording order of the slot

SLOT SEL

SLOT1

when the power is turned on.

 

 

 

 

 

 

HOLD:

 

 

 

 

 

 

The recording order starts with the

 

 

 

 

 

 

card previously selected when the

 

 

 

 

 

 

power was turned off.

 

 

 

 

 

 

SLOT1:

 

 

 

 

 

 

The recording order starts with the

 

 

 

 

 

 

card that is inserted in Slot 1 when the

C

U

F

 

 

power is turned on.

Note

Displayed REC TIME, PAUSE TIME and TOTAL REC TIME are translated into either drop-frame or non-drop-frame according to the mode of operation.

TAKE TOTAL TIME is actual time. Therefore, TOTAL REC TIME may incorporate fractions, depending on the settings.

Example of drop-frame

REC TIME

02s00f

 

 

PAUSE TIME

02s00f

 

 

TAKE TOTAL TIME

40min

 

 

TOTAL REC TIME

19m59s06f

 

 

164 Menu: Menu Description Tables