11. P2 Card Nearly Full

Display window

One of the bars for remaining MEDIA capacity

indication

starts blinking.

 

 

WARNING lamp

Blinks once per second while recording

continues.

 

 

 

Tally lamp

Blinks once per second while recording

continues.

 

 

 

Viewfinder

The P2 card remaining capacity indicator blinks.

 

 

Warning tone

Beeps once per second while recording

continues.

 

 

 

Warning

The total remaining capacity of all the P2

description

cards is two minutes or less.

 

 

Recording/

 

playback

Continues to operate.

operation

 

 

 

Countermeasures

Replace the cards. If there is an empty card

 

slot, insert a new card.

12. P2 Card Error

Display window

Displays “00:00:00:11” in the time code

display. The window continues to flash until

indication

the next operation, even after stopping record

 

and playback.

 

 

 

If the error occurs during recording, the lamp

WARNING lamp

flashes four times per second for a period of

about three seconds. The lamp does not light

 

 

if the error occurs during playback.

 

 

 

If the error occurs during recording, the lamp

Tally lamp

flashes four times per second for a period of

about three seconds. The lamp does not light

 

 

if the error occurs during playback.

 

 

 

A flashing “CARD ERR ¢” appears. In the actual

Viewfinder

indication the ¢ is replaced by the slot number of

 

the P2 card that triggered the error.

 

 

 

If the error occurs during recording, the tone

Warning tone

sounds four times per second for a period of

about three seconds. The tone does not

 

 

sound if the error occurs during playback.

 

 

Warning

An error has occurred while recording data to

description

or playing data from a P2 card.

 

 

Recording/

Stop recording or playback. After recording is

playback

stopped, the P2 card where error occurs is

operation

write protected.

 

 

Countermeasures

Replace the affected P2 card.

 

 

13. FAN STOP

Display window

No display.

 

 

indication

 

 

 

 

 

 

 

WARNING lamp

Blinks 4 times per second.

 

 

 

 

 

Tally lamp

No display.

 

 

 

 

 

Viewfinder

The FAN STOP indicator blinks while

 

 

recording continues.

 

 

 

 

 

 

 

Warning tone

It does not sound.

 

 

 

 

 

 

The fan is at rest because something is wrong

 

 

Warning

with it. Alternatively, the FAN MODE item is

 

set to “OFF”. The menu item FAN MODE is

 

 

description

 

found in the <OPTION> screen on the

 

 

 

 

 

OPTION MENU page.

 

 

 

 

Recording/

If the camera-recorder operates with the fan

 

 

stopped, then the temperature inside rises.

 

playback

While the camera-recorder continues to

 

operation

operate, clips may not be recorded or played

 

 

 

 

back properly.

 

 

 

 

 

Countermeasures

Immediately stop using the camera-recorder

 

InspectionsandMaintenance

 

and consult your distributor.

 

 

 

Error Codes

The following error codes are displayed in the display window if an error occurs in the camera:

Confirm the type of warning and refer to the details in the [Warning Description Tables] (page 153) for countermeasures.

Code No.

Description

 

Type of warnings

 

 

 

 

 

 

 

E-11

Video initialisation error

1. System Errors

 

 

 

 

E-27

Recording control error

1. System Errors

 

 

 

 

E-30

P2 card removal error

2.

Card removal error

 

 

 

E-34

LCD microcontroller error

1. System Errors

 

 

 

E-38

P2 streaming microcontroller error

1. System Errors

 

 

 

E-3F

Microprocessor error in the camera control circuit.

1. System Errors

 

 

 

E-40

Image sequence, GENLOCK input signal or SDI input signal error

5. Image Sequence Error, 6. Corruption of Standard Signal

 

 

 

E-63

Something is wrong with the system control microprocessor.

1. System Errors

 

 

 

E-6F

Reference signal error.

1. System Errors

 

 

 

00:00:00:11

Errors such as recording to P2 card error

7. Recording Error, 8. Number of Clips Exceeded,

 

 

12. P2 Card Error

 

 

 

 

 

Maintenance and Inspections: Warning System 155