BATTERY SETTING (1/2)

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

 

HYTRON140

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

11.0

 

When MANUAL is selected in the menu

 

 

 

 

 

:

 

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.5

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

DIONIC90

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

11.0

 

When MANUAL is selected in the menu

 

 

 

 

 

:

 

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.4

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

 

DIONIC160

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

11.0

 

When MANUAL is selected in the menu

 

 

 

 

 

:

 

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.6

V steps.

 

 

 

 

 

:

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

 

ENDURA10

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

11.0

 

When MANUAL is selected in the menu

 

 

 

 

 

:

 

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.4

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

PAG L95

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

 

 

 

 

AUTO

Select auto or manual to set the NEAR

 

 

 

 

 

MANUAL

END voltage.

 

 

 

 

 

 

 

AUTO: Set voltage automatically.

 

 

 

 

 

 

 

MANUAL:Set voltage manually.

 

 

 

 

 

11.0

 

When MANUAL is selected in the menu

 

 

 

 

 

:

 

above, set the NEAR END voltage in 0.1

 

 

 

 

 

13.6

V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

BATTERY SETTING (2/2)

 

Items/

Adjustable

Remarks

Data Saved

Range

 

 

 

 

 

TYPE A

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

FULL

12.0

Set the voltage to display the FULL

 

 

 

 

 

:

 

indication in 0.1 V steps.

 

 

 

 

 

15.3

 

 

 

 

 

 

:

 

 

 

 

 

 

 

17.0

 

 

NEAR END

11.0

 

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.6

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

 

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

13.2

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

TYPE B

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

FULL

12.0

Set the voltage to display the FULL

 

 

 

 

 

:

 

indication in 0.1 V steps.

 

 

 

 

 

15.5

 

 

 

 

 

 

:

 

 

 

 

 

 

 

17.0

 

 

NEAR END

11.0

 

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.5

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

 

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

13.1

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

TYPE C

¢

 

Enable selection under BATTERY

 

 

 

 

 

SELECT.

 

 

 

 

 

 

 

¢:Enable selection.

 

 

 

 

 

 

 

: Disable selection.

 

FULL

12.0

Set the voltage to display the FULL

 

 

 

 

 

:

 

indication in 0.1 V steps.

 

 

 

 

 

15.6

 

 

 

 

 

 

:

 

 

 

 

 

 

 

17.0

 

 

NEAR END

11.0

 

Set the NEAR END voltage in 0.1 V

 

 

 

 

 

:

 

steps.

 

 

 

 

 

13.9

 

 

 

 

 

 

:

 

 

 

 

 

 

 

15.0

 

 

END

11.0

 

Set the END voltage in 0.1 V steps.

 

 

 

 

 

:

 

 

 

 

 

 

 

13.6

 

 

 

 

 

 

:

 

 

C

U

F

15.0

 

 

 

 

 

 

 

 

 

zThe remaining battery level is indicated in percentage when a battery with this function is installed on the unit.