Self-diagnosis display

There is a self-diagnosis display located at the side of the projector (p. 15) which automatically displays error details when an error occurs.

Self-

Details

 

Remedy

diagnosis

 

display

 

 

 

U04

Air filter is blocked

Clean the air filter unit.

U11

Intake air temperature warning

 

 

U12

Optical module temperature warning

 

 

U13

Lamp ambient temperature warning

 

 

U14

Low temperature warning

Ambient air temperature is too high.

U21

Intake air temperature error

 

 

U22

Optical module temperature error

 

 

U23

Lamp ambient temperature error

 

 

U24

Low temperature error

Ambient temperature is too low.

U41

Lamp 1 operating time warning

 

 

U42

Lamp 2 operating time warning

The lamp replacement period has arrived. Replace the

U43

Lamp 3 operating time warning

 

lamp.

U44

Lamp 4 operating time warning

 

 

U51

Lamp 1 error

 

 

U52

Lamp 2 error

Lamp has not turned on.

U53

Lamp 3 error

 

 

U54

Lamp 4 error

 

 

U61

Lamp 1 : 2000 hour operating time exceeded

 

 

U62

Lamp 2 : 2000 hour operating time exceeded

The lamp has exceeded its replacement period.

U63

Lamp 3 : 2000 hour operating time exceeded

 

Replace the lamp straight away.

U64

Lamp 4 : 2000 hour operating time exceeded

 

 

U70

Air filter unit not installed

Install the air filter unit.

U71

Lamp 1 not installed

 

 

U72

Lamp 2 not installed

Install the lamp.

U73

Lamp 3 not installed

 

 

U74

Lamp 4 not installed

 

 

 

AC power supply voltage drop warning (less

AC power supply voltage input has dropped. Check

U81

 

that there is sufficient electrical wiring capacity for the

than 90 V)

 

 

 

projector’s power consumption requirements.

 

 

 

 

 

 

 

U91

Lamp unit cover is not closed

Close the lamp unit cover.

H01

Internal clock battery replacement

The battery needs to be replaced. Consult your dealer.

H11

Air intake temperature sensor not found

 

 

H12

Optical module temperature sensor not found

 

 

H13

Lamp ambient temperature sensor not found

 

 

H18

Air flow sensor not found

 

 

F11

Shutter error

If turning the main power off and back on again does

F12

Dynamic iris error

 

not clear the error display, consult your dealer.

F13

Air filter unit error

 

 

F21

2.5 V DC error

 

 

F22

3.3 V DC error

 

 

F23

5.0 V DC error

 

 

114 ENGLISH

Page 114
Image 114