Contents of mail sent

Mail with the contents shown below is sent when the E-mail settings have been established.

 

Subject: Panasonic projector report(CONFIGURE)

 

 

 

 

 

 

=== Panasonic projector report(CONFIGURE) ===

 

 

 

 

 

Projector Type

 

 

: D10000

 

 

 

 

 

 

 

 

-----

E-mail setup data -----

 

 

 

 

 

 

 

 

TEMPRATURE WARNING SETUP

 

 

 

 

 

 

 

 

 

 

MINIMUM TIME

 

 

at [ 60] minutes interval

 

 

 

 

INPUT AIR TEMPERATURE

Over [ 35C / 95F ]

 

 

 

 

 

 

OUTPUT AIR TEMPERATURE

Over [ 60C / 140F ]

 

 

 

 

 

 

ERROR

 

 

 

[ OFF ]

 

 

 

 

 

 

 

 

LAMP1 RUNTIME

 

 

[ OFF ]

at REMAIN [ 200] H

 

 

 

 

LAMP1 RUNTIME

 

 

[ OFF ]

at REMAIN [ 100] H

 

 

 

 

LAMP2 RUNTIME

 

 

[ OFF ]

at REMAIN [ 200] H

 

 

 

 

LAMP2 RUNTIME

 

 

[ OFF ]

at REMAIN [ 100] H

 

 

 

 

LAMP3 RUNTIME

 

 

[ OFF ]

at REMAIN [ 200] H

 

 

 

 

LAMP3 RUNTIME

 

 

[ OFF ]

at REMAIN [ 100] H

 

 

 

 

LAMP4 RUNTIME

 

 

[ OFF ]

at REMAIN [ 200] H

 

 

 

 

LAMP4 RUNTIME

 

 

[ OFF ]

at REMAIN [ 100] H

 

 

 

 

INPUT AIR TEMPERATURE

[ OFF ]

 

 

 

 

 

 

 

 

OUTPUT AIR TEMPERATURE

[ OFF ]

 

 

 

 

 

 

 

 

PERIODIC REPORT

 

 

 

 

 

 

 

 

 

 

 

Sunday

[ OFF ]

Monday

[ OFF ]

Tuesday

[ OFF ] Wednesday [ OFF ]

 

 

Thursday [ OFF ]

Friday

[ OFF ]

Saturday

[ OFF ]

 

 

 

00:00

[ OFF ]

 

01:00

[ OFF ]

02:00

[ OFF ]

03:00

[ OFF ]

 

 

04:00

[ OFF ]

 

05:00

[ OFF ]

06:00

[ OFF ]

07:00

[ OFF ]

 

 

08:00

[ OFF ]

 

09:00

[ OFF ]

10:00

[ OFF ]

11:00

[ OFF ]

 

 

12:00

[ OFF ]

 

13:00

[ OFF ]

14:00

[ OFF ]

15:00

[ OFF ]

 

 

16:00

[ OFF ]

 

17:00

[ OFF ]

18:00

[ OFF ]

19:00

[ OFF ]

 

 

20:00

[ OFF ]

 

21:00

[ OFF ]

22:00

[ OFF ]

23:00

[ OFF ]

 

 

-----

check system -----

 

 

 

 

 

 

 

 

 

MAIN CPU BUS

 

 

[

OK

]

 

 

 

 

 

 

 

FAN

 

 

 

[

OK

]

 

 

 

 

 

 

 

OPTICS MODULE TEMPERATURE [

OK

]

 

 

 

 

 

 

 

INPUT AIR TEMPERATURE

[

OK

]

 

 

 

 

 

 

 

OUTPUT AIR TEMPERATURE

[

OK

]

 

 

 

 

 

 

 

LAMP1 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP2 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP3 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP4 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mail with the contents shown below is sent when an error has occurred.

 

Subject: Panasonic projector report(ERROR)

 

 

 

 

 

 

 

=== Panasonic projector report(ERROR) ===

 

 

 

 

 

 

Projector Type

 

: D10000

 

 

 

 

 

 

 

 

----- check system -----

 

 

 

 

 

 

 

 

 

 

MAIN CPU BUS

 

 

[

OK

]

 

 

 

 

 

 

 

FAN

 

 

 

[

OK

]

 

 

 

 

 

 

 

OPTICS MODULE TEMPERATURE

[

OK

]

 

 

 

 

 

 

 

INPUT AIR TEMPERATURE

[

OK

]

 

 

 

 

 

 

 

OUTPUT AIR TEMPERATURE

[

OK

]

 

 

 

 

 

 

 

LAMP1 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP2 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP3 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP4 REMAIN TIME

 

[

OK

]

 

 

 

 

 

 

 

LAMP1 STATUS

 

 

[ FAILED

]

 

 

 

 

 

 

 

LAMP2 STATUS

 

 

[

OK

]

 

 

 

 

 

 

 

LAMP3 STATUS

 

 

[

OK

]

 

 

 

 

 

 

 

LAMP4 STATUS

 

 

[

OK

]

 

 

 

 

 

 

 

APERTURE(CONTRAST-SHUTTER) [

OK

]

 

 

 

 

 

 

 

SHUTTER(MUTE-SHUTTER)

[

OK

]

 

 

 

 

 

 

 

DIRTY AIR FILTER

 

 

[

OK

]

 

 

 

 

 

 

 

AIR FILTER CLEANER UNIT

[

OK

]

 

 

 

 

 

 

 

OPTICS MODULE TEMP.SENSOR

[

OK

]

 

 

 

 

 

 

 

INPUT AIR TEMP.SENSOR

[

OK

]

 

 

 

 

 

 

 

OUTPUT AIR TEMP.SENSOR

[

OK

]

 

 

 

 

 

 

 

BATTERY

 

 

 

[

OK

]

 

 

 

 

 

 

 

AIRFLOW SENSOR

 

 

[

OK

]

 

 

 

 

 

 

 

AC POWER

 

 

 

[

OK

]

 

 

 

 

 

 

 

(Error code 00 00 00 00 00 00 00 00

00 00 00 00 00 01 00 00)

 

 

 

Input air temperature

: 29 degC /

84 degF

 

 

 

 

 

Optics module temperature

: 33 degC /

91 degF

 

 

 

 

 

Output air temperature

: 29 degC /

84 degF

 

 

 

 

 

SET RUNTIME

 

17 H

 

 

 

 

 

 

 

 

 

 

POWER ON

 

 

9 times

 

 

 

 

 

 

 

 

 

LAMP1 ON

 

 

8 times

 

 

 

 

 

 

 

 

 

LAMP1 HIGH

 

11 H

 

 

 

 

 

 

 

 

 

 

LAMP2 ON

 

 

0 times

 

 

 

 

 

 

 

 

 

LAMP2 HIGH

 

0 H

 

 

 

 

 

 

 

 

 

 

LAMP3 ON

 

 

1 times

 

 

 

 

 

 

 

 

 

LAMP3 HIGH

 

1 H

 

 

 

 

 

 

 

 

 

 

LAMP4 ON

 

 

1 times

 

 

 

 

 

 

 

 

 

LAMP4 HIGH

 

0 H

 

 

 

 

 

 

 

 

 

 

LAMP1 REMAIN

1989 H

 

 

 

 

 

 

 

 

 

 

LAMP2 REMAIN

2000 H

 

 

 

 

 

 

 

 

 

 

LAMP3 REMAIN

1999 H

 

 

 

 

 

 

 

 

 

 

LAMP4 REMAIN

2000 H

 

 

 

 

 

 

 

 

 

 

-------- Current status ---------

 

 

 

 

 

 

 

 

MAIN VERSION

 

1.00

 

 

 

 

 

 

 

 

 

 

NETWORK VERSION

 

1.00

 

 

 

 

 

 

 

 

 

 

----- Network configuration -----

 

 

 

 

 

 

 

 

DHCP Client

OFF

 

 

 

 

 

 

 

 

 

 

 

IP address 192.168.0.8

 

 

 

 

 

 

 

 

 

 

MAC address 00:0B:97:41:E2:4E

 

 

 

 

 

 

 

 

 

Wed Oct 11 18:21:44 2006

 

 

 

 

 

 

 

 

 

 

----- Memo -----

 

 

 

 

 

 

 

 

 

 

 

Special Features

ENGLISH 95

Page 95
Image 95
Panasonic PT-DW10000E, PT-D10000E manual Special Features, Contents of mail sent