4. Monitoring the Unit

Table 4-1. Health and Status Messages (2 of 2)

Message

What Message Indicates

What To Do

 

 

 

 

Net Com Link Down

The Network communication

1.

Verify that the network cable

 

link is down.

 

is securely attached at both

 

Communications between

 

ends.

 

the management system and

2.

Verify the link protocol for the

 

the LTU/NTU is not possible.

 

 

COM port is configured

 

 

 

 

 

 

correctly.

 

 

 

 

Net Margin Threshold,

The signal-to-noise margin

1.

Check the Network

Pt n

has exceeded the configured

 

Performance Statistics

 

threshold.

 

screen for possible line

 

 

 

impairments.

 

 

2.

Set the unit to run at a lower

 

 

 

DSL line rate.

 

 

3.

Contact network provider.

 

 

 

NTU/LTU Mis match,

The NTU is not configured

Configure units to match.

Pt n

compatibly with the LTU.

 

 

 

 

 

 

OOF at Net, Pt n

Three consecutive frame

1.

Check the Transmit Clock

 

synchronization bits were in

 

Source configuration options.

 

error.

 

Do not set both the local and

 

 

 

remote unit to Internal,

 

 

 

External, or Loop timing.

 

 

2.

Set the unit to run at a lower

 

 

 

DSL line rate.

 

 

3.

Contact network provider.

 

 

 

 

Prim Clk Failed Pt n

A failure has occurred in the

1.

Verify that the network cable

 

primary clock source

 

is securely attached at both

 

configured from the Network,

 

ends.

 

DSX, or from the card

2.

Contact network provider.

 

internal clock.

 

 

 

 

 

 

System Operational

There are no problems

No action is needed.

 

detected.

 

 

 

 

 

 

Yellow at DSX-1, Pt n

A Yellow Alarm Indication

1.

Verify that the unit’s line

 

signal is being received by

 

framing and line coding are

 

the DSX-1 interface.

 

compatible.

 

 

2.

Contact network provider.

 

 

 

 

4-4

February 2001

8784-A2-GB20-30

Page 40
Image 40
Paradyne 8784 manual Monitoring the Unit