Security

7

Overview

he termination unit provides several methods of security by limiting user access to the ATI through option settings. You can:

Enable the Telnet Login Required option.

Limit the access by setting a Session Access Level option of Operator for the

TTelnet Session.

Disable the access with the Telnet Session option.

See Table A-5, Telnet Session Options, in Appendix A, Configuration Options.

ATI Access Levels

The unit has two access levels: Administrator and Operator. The access level determines what functions are accessible, as shown in Table 7-1, Access Levels.

Table 7-1. Access Levels

ATI Access to Menu Functions

Administrator

Operator

 

 

 

Status

Read-Only

Read-Only

 

 

 

Test

Full Access

No Access

 

 

 

Configuration

Full Access

Read-Only

 

 

 

Control

Full Access

No Access

 

 

 

Access level is also used to control access via Telnet. If the Telnet Session Access Level is set to Administrator, a Login ID with an Operator access level is not permitted access (see Table A-5, Telnet Session Options, in Appendix A, Configuration Options).

The effective access level is the more restrictive of the session access level or the login access level.

8784-A2-GB20-30

February 2001

7-1

Page 69
Image 69
Paradyne 8784 manual Security, ATI Access Levels