4. Monitoring the Unit

Front Panel LEDs

SYSTEM

O

K

A lrm

T e st

DSX - 1

1

2

DSL PORT 1

2

TDM

SDSL

8784

The following table describes the meaning and states of the LEDs on the faceplate.

Type

LED

LED is . . .*

Indicating . . .

 

 

 

 

SYSTEM

OK

On

Device failure; system processing has

 

(Green)

 

stopped.

 

 

Off

No power is being delivered to the card.

 

 

Slow Cycling

Unit is in minimum mode and a download

 

 

 

is required.

 

 

Pulsing

Normal operation.

 

 

 

 

 

Alrm

On

Device failure, or the Power-On Self-Test

 

(Amber)

 

(POST) has failed.

 

 

Off

No alarms exist.

 

 

 

 

 

Test

On

Loopback test or 511 test pattern is

 

(Amber)

 

in progress.

 

 

Slow cycling

POST is in progress.

 

 

Off

No tests are active.

 

 

 

 

DSX-1

1, 2

On

Recoverable signal is present on the

 

(Green)

 

DSX-1 interface.

 

 

Slow cycling

Yellow Alarm Indication (RAI) is present.

 

 

Fast cycling

An OOF, LOF, EER, or AIS condition

 

 

 

exists.

 

 

Off

No signal is detected on the interface.

 

 

 

 

DSL PORT

1, 2

On

DSL link is up.

 

(Green)

Slow cycling

DSL training is in progress.

 

 

 

 

Fast cycling

OOF condition exists.

 

 

Off

DSL link is down.

 

 

 

 

*Slow Cycling: LED turns off and on in equal duration once per second.

Fast Cycling: LED turns off and on in equal duration 5 times per second.

Pulsing: LED turns off momentarily once per second.

00-16144a-01

4-14

February 2001

8784-A2-GB20-30

Page 50
Image 50
Paradyne 8784 manual Front Panel LEDs, Type, LED is Indicating