5. Testing

Ending an Active Test

Except for the Remote Send Line Loopback, a test initiated by the user can be ended by the user.

TA test initiated by the user can be ended using:

Test Timeout option – Enable the Test Timeout system option so the unit can automatically terminate tests, and set the Test Duration (min) option to specify the amount of time that tests can run before the unit terminates the test. The default is 10 minutes. Refer to Table A-4, System Options, in Appendix A,

TConfiguration Options.

Command column – Under the Command column on any test screen, position the cursor at Stop next to the active test and press Enter to stop a

Tspecific test.

Abort All Tests menu selection – Select Abort All Tests from the Test menu to stop all tests running on all interfaces. Command Complete appears when all tests on all interfaces have been terminated. Network-initiated loopbacks cannot be stopped from the Test menu.

An aborted test may continue to run for a few seconds as the Stop command is sent to the remote end and processed.