Paradyne 8784 manual Viewing System and Test Status, Main Menu→ Status→ System and Test Status

Models: 8784

1 110
Download 110 pages 56.67 Kb
Page 38
Image 38
Viewing System and Test Status

4. Monitoring the Unit

Viewing System and Test Status

To view System and Test Status information, follow this menu selection sequence:

Main MenuStatusSystem and Test Status

main/status/system

 

Hotwire

Slot: 4

 

Model: 8784

 

SYSTEM AND TEST STATUS

Page 1 of 1

HEALTH AND STATUS

SELF-TEST RESULTS

TEST STATUS

-------------------------------------------------------------------------------

LOS at Net, Pt n

CPU Failed

No Test Active

OOF at Net, Pt n

Device Failed

LLB Test Active, Pt n

EER at Net, Pt n

Net DSL Failed, Pt n

RLB Test Active, Pt n

LOS at DSX-1 Pt n

DSX-1 Pt Failed, Pt n

Lamp Test Active

Net Margin Threshold, Pt n

Memory Failed

DLB Test Active, Pt n

Device Failed yyyyyyyy

Passed

 

Download Failed

 

 

-------------------------------------------------------------------------------

ESC for previous menu

MainMenu Exit

he System and Test Status screen has three sections:

Health and Status – Displays messages in priority order (highest to lowest).

Refer to Table 4-1, Health and Status Messages.

Self-Test Results – Results of the Diagnostic test run on the device itself.

TRefer to Table 4-2,Self-Test Results Messages.

Test Status – Currently active tests. Refer to Table 4-3, Test Status Messages.

4-2

February 2001

8784-A2-GB20-30

Page 38
Image 38
Paradyne 8784 manual Viewing System and Test Status, Main Menu→ Status→ System and Test Status