5. Testing

Send and Monitor 511

The Send and Monitor 511 test causes the local and remote units to send a 511 test pattern to each other. The front panel Test LEDs of both units are on during the test. The duration and results of the test are displayed on the Network & DSX-1 Tests screen of the initiating unit.

NOTE:

The Send and Monitor 511 test is not a loopback test. Each unit independently sends and monitors a 511 pattern.

AIS

LIU

T1

Framer

CAP

Framer

CAP

511

Gen

511

Mon

Transceiver

511

Pattern

511

Pattern

CAP

511

Mon

511

Gen

Transceiver

CAP

Framer

T1

Framer

LIU

AIS DSX-1 Port

98-16108

Procedure

To run a Send and Monitor 511 test:

1.Position the cursor at the Start command next to Send and Monitor 511 on the Network & DSX-1 Tests screen.

2.Press Enter.

The Start command is changed to Stop.

3.To manually stop the test, verify that the cursor is positioned at the Stop command.

4.Press Enter.

When a Send and Monitor 511 test is active, a count of bit errors is displayed next to the test duration, and the ResetMon virtual function key is available for use. Type r or R or select the ResetMon virtual function key to reset the error count.

8784-A2-GB20-30

February 2001

5-7

Page 57
Image 57