Paradyne 8784 manual Running Network Tests, Main Menu→ Test→ Network & DSX-1 Tests

Models: 8784

1 110
Download 110 pages 56.67 Kb
Page 52
Image 52
Running Network Tests

5. Testing

Running Network Tests

Network tests require the participation of your network service provider.

To access the Network & DSX-1 Tests screen, follow this menu selection sequence:

Main MenuTestNetwork & DSX-1 Tests

main/test/network_DSX1

 

Hotwire

Slot: 4

 

Model: 8784

Port: 2

 

 

 

NETWORK & DSX-1 TESTS

 

Test

Command Status

Results

--------------------------------------------------------------------------------

Local Loopbacks

 

 

 

Line

Loopback:

Start

Inactive

00:00:00

DSX-1 Repeater Loopback:

Start

Inactive

00:00:00

DSX-1 DTE Loopback:

Start

Inactive

00:00:00

Remote

Loopbacks

 

 

 

Send

Line Loopback: Down

Send

Inactive

00:00:00

Pattern Tests

 

 

 

Send

and Monitor 511

Stop

Active

hh:mm:ss - Errors 99999+

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu

MainMenu

Exit

ResetMon

 

 

Use the Command column to start or stop a test. When the Status column shows that a test is Inactive, Start is displayed; when a test is Active, Stop is displayed. Position the cursor at the desired Start or Stop command and press Enter. The Results column displays the test duration.

When the Send and Monitor 511 test is active, ResetMon is available to reset the error counter to zero.

Selecting Abort All Tests from the Test menu will not disrupt a Send and

Monitor 511 test.

5-2