Paradyne 8784 manual Viewing DSX-1 Performance Statistics, 4-11

Models: 8784

1 110
Download 110 pages 56.67 Kb
Page 47
Image 47
Viewing DSX-1 Performance Statistics

4. Monitoring the Unit

Fields on this screen include:

Field . . .

Contains . . .

 

 

Current Interval

The number of seconds which have elapsed in the current

Timer

15-minute interval. Maximum value is 900 seconds (15 minutes).

 

This counter is reset every 15 minutes.

 

When zero, the port is disabled.

 

 

Payload Rate

The rate of data transfer.

 

 

DSL Line Rate

The rate of the DSL line.

 

 

Viewing DSX-1 Performance Statistics

DSX-1 performance statistics allow you to monitor the current status of the DSX-1 interface when ESF framing is selected.

To view DSX-1 Performance Statistics, follow this menu selection sequence:

Main MenuStatusPerformance StatisticsDSX-1 Statistics

main/status/performance/DSX-1

Hotwire

Slot:

4

 

Model: 8784

Port:

2

DSX-1 PERFORMANCE STATISTICS

Current Interval Timer: 2

Error Events Counter: 0000

--------------------------------------------------------------------------------

 

 

--ES--

--UAS--

--SES--

--BES--

--LOFC--

--STATUS--

Current Int:

000

000

000

000

000

Y

Interval

01

000

000

000

000

000

none

Interval

02

000

000

000

000

000

none

Interval

03

000

000

000

000

000

none

Interval

04

000

000

000

000

000

none

Interval

05

000

000

000

000

000

none

Interval

06

000

000

000

000

000

none

Interval

07

000

000

000

000

000

none

Worst Interval:

24

14

14

09

18

 

Tot(valid 96):

00010

00000

00000

00000

002

 

--------------------------------------------------------------------------------

Ctrl-a to access these functions, ESC for previous menu

MainMenu Exit

PgUp

PgDn

ClrStats

 

he following DSX-1 Performance Statistics are collected:

ES (Errored Seconds): Seconds during which one or more error events

Toccurred.

UAS (Unavailable Seconds): Seconds during which service is unavailable. UAS is received at the start of 10 consecutive SES and cleared at the start of

T10 seconds with no SES.

SES (Severely Errored Seconds): Seconds during which 320 or more cyclic redundancy check (CRC) error events or at least one Out of Frame (OOF) event occurred.

8784-A2-GB20-30

February 2001

4-11

Page 47
Image 47
Paradyne 8784 Viewing DSX-1 Performance Statistics, 4-11, Main Menu→ Status→ Performance Statistics→ DSX-1 Statistics