3. Initial Startup and Configuration

Resetting AutoRate

The Reset AutoRate function on the Control menu causes the unit to repeat the AutoRate sequence. The unit attempts to establish the DSL link at the highest rate (or the value of DSL Line Rate, which represents the AutoRate ceiling when AutoRate is enabled). If the link fails, the next lower rate is tried until the link is established.

To access the Reset AutoRate screen, follow this menu selection sequence:

Main MenuControlReset AutoRate

Restoring Access to the User Interface

Improper configuration of the unit could render the user interface inaccessible. If this occurs, access can be restored using the MCC.

Procedure

To reset the DSL Card:

1.Select ConfigurationDSL Cards Reset Slot.

2.Enter DSLnn, where nn is the slot number for the DSL card you wish to reset.

3.Enter Reset.

4.Enter Y if you want to clear NVRAM also, otherwise enter N. Entering Y restores the Default Factory Configuration.

5.Enter Y at the prompt to confirm.

NOTE:

When you enter Y, all data connectivity is interrupted.

You can also restore access to the user interface by reloading the Default Factory Configuration options using the unit’s menus.

Procedure

To restore access to the ATI using the unit’s menus:

Main MenuConfigurationDefault Factory Configuration