Paradyne 8784 manual TifOperStatus RFC

Models: 8784

1 110
Download 110 pages 56.67 Kb
Page 96
Image 96
TifOperStatus (RFC 1573)

B. Standards Compliance for SNMP Traps

The tests that affect the enterpriseTestStart, enterpriseTestStop, and the variable-bindings are different for each particular interface. Diagnostic tests are only supported on the physical T1 network and user data port interfaces. The specific tests and variable-bindings are described in the following table:

 

enterpriseTestStart/Stop

 

 

Interface

Variable-Bindings

Possible Cause

 

 

 

DSL Network

ifIndex (RFC 1573)

TenterpriseTest Start – Any

 

ifAdminStatus (RFC 1573)

one of the following tests is

 

active on the interface:

 

 

 

 

ifOperStatus (RFC 1573)

Line Loopback

 

TifType (RFC 1573)

Repeater Loopback

 

ifTestType (RFC 1573)

Remote Line Loopback

 

T

Send and Monitor 511

 

The following objects control tests

 

in SNMP-managed devices:

enterpriseTest Stop – No

 

– noTest – Stops the test in

tests currently running on

 

 

progress.

the interface.

 

– testLoopLLB – Initiates a Local

 

 

 

 

Loopback.

 

 

 

testLoopRLB – Initiates a

 

 

 

 

Remote Loopback.

 

 

 

testSendMon511 – Initiates a

 

 

 

 

Send and Monitor 511 test.

 

 

 

– testSendLLBUp – Initiates an

 

 

 

 

LLB Up message to the

 

 

 

 

remote unit.

 

 

 

testSendLLBDown – Initiates

 

 

 

 

an LLB Down message to the

 

 

 

 

remote unit.

 

 

 

 

 

DSX-1

ifIndex (RFC 1573)

TenterpriseTest Start – Any

 

ifAdminStatus (RFC 1573)

one of the following tests is

 

active on the interface:

 

 

 

 

TifOperStatus (RFC 1573)

Data Terminal

 

ifTestType (RFC 1573)

 

Loopback

 

Repeater Loopback

 

The following objects control tests

 

testLoop RLB – initiates

 

in SNMP-managed devices:

 

– noTest – Stops the test in

 

a Repeater Loopback

 

testLoop DTLB –

 

 

progress.

 

testLoopExternalDTE

 

initiates a DSX-1 DTE

 

T

Loopback

 

 

 

enterpriseTest Stop – No

 

 

 

tests currently running on

 

 

 

the interface.

 

 

 

 

 

B-4

February 2001

8784-A2-GB20-30

Page 96
Image 96
Paradyne 8784 manual TifOperStatus RFC