Patton electronic user manual OnSite 2800 Series factory configuration

Models: 2800

1 135
Download 135 pages 34.01 Kb
Page 133
Image 133

OnSite 2800 Series User Manual

E • OnSite 2800 Series factory configuration

 

 

Introduction

The factory configuration settings for the OnSite 2800 Series devices are as follows:

#----------------------------------------------------------------

#

#2800 Series

#R3.xx BUILDxxxxx

#2005-01-18T00:00:00

#Factory configuration file

#----------------------------------------------------------------

#

profile

napt NAPT

profile

dhcp-server DHCP

network

192.168.1.0 255.255.255.0

include

192.168.1.10 192.168.1.19

lease

2

hours

default-router 192.168.1.1

context

ip router

interface eth0

ipaddress 172.16.40.1 255.255.0.0 use profile napt NAPT

interface eth1

ipaddress 192.168.1.1 255.255.255.0

context ip router dhcp-server use DHCP

port ethernet 0 0 medium auto encapsulation ip

bind interface eth0 router no shutdown

port ethernet 0 1 medium auto encapsulation ip

bind interface eth1 router no shutdown

Introduction

133

Page 133
Image 133
Patton electronic user manual OnSite 2800 Series factory configuration