Pitney Bowes D1500 OMR Scanner Adjustments, Aligning the Scanners, Measure the OMR mark position

Models: D1500 D1600

1 118
Download 118 pages 53.49 Kb
Page 76
Image 76

5 • Optical Mark Recognition (OMR)

OMR Scanner Adjustments

The machine can be fitted with one Top Scanner and one Bottom Scanner. If the sheet(s) bearing OMR marks are loaded face up, the Top Scanner will be used. If they are loaded face down, the Bottom Scanner will be used. The loading orientation required for the particular job will be shown on the Mail Piece Icon Tree and depends on fold type, etc.

Aligning the Scanners

It is essential that the OMR Scanner being used is correctly aligned over the OMR marks printed on the sheet(s). Failure to align the scanner will result in scanning errors. It is therefore essential that the scanner alignment is checked before commencing any OMR job.

Measure the OMR mark position

Take a sheet printed with the OMR marks to be used and fold it in half in the direction of feed to locate the sheet’s center line. Now measure from the center line to the center of the OMR marks in millimetres. Take a note of this measurement (X).

OMR marks (position used depends on scanner location)

X mm

X mm

Folded center line