Polycom RMX 2000 Administrator’s Guide
2-75
For more details on the definition of new Entry Queues refer to the
MGC Manager User’s Guide, Volume II, Chapter 1, “Ad Hoc Auto
Cascading and Cascading Links”.
4Click OK.
Creating the Dial-out Link between the Conference Running on the
MGC and the Conference Running on the RMX
If the dialing is done from the MGC to the RMX, you need to define the
cascaded link (dial-out participant) in the conference running on the
MGC.
The dial-out string defined for the participant is the dialing string
required to connect to the destination conference via the Cascade-enabled
Entry Queue defined on the RMX hosting the destination cascaded
conference. The dial-out participant can be defined on the MGC as
template or assigned to the Meeting Room.
In the MGC Manager application, define a new participant as follows:
1In the Participant Properties - Identification dialog box, enter a
Participant Name
2In the Connection Type field, select Dial-out.
3In the Interface Type list field, select H.323.
4There are two methods to define the dialing string to the other
conference:
aUsing the MCU’s IP Address and the Alias string.
bUsing only the Alias string (requires a gatekeeper).
Method A (If no gatekeeper is used):
In the IP Address field, enter the IP address of the Signaling Host of
the RMX 2000 hosting the destination conference.
In the Alias Name/Type field, enter the ID of the cascade-enabled Entry
Queue (EQ), the Conference ID and Password of the destination
conference as follows:
EQ ID##Destination Conference ID##Password (Password is
optional).
For Example: 1002##12001##1234
Cascade-enabled
EQ ID
Destination
Conference ID
Password (optional)