Serial Communications

Table 6-1. Serial Commands (continued)

 

Command

Value Range

Description

 

 

 

 

 

ASCII

 

HEX

Minimum

Maximum

 

 

 

 

 

 

 

CLMS01

 

43 4C 4D 53 30 31

Sets the ISF SETTING to ISF CCC.

 

 

 

 

 

 

FCA

 

46 43 41

Sets FAN SPEED to AUTO.

 

 

 

 

 

 

FDT

 

46 44 54

Executes FUNCTION RESET.

 

 

 

 

 

 

FCM

 

46 43 4D

Sets FAN SPEED to MAX.

 

 

 

 

 

 

FMKS00

 

46 4D 4B 53 30 30

Sets the TEST PATTERN to OFF.

 

 

 

 

 

 

FMKS02

 

46 4D 4B 53 30 32

Sets the TEST PATTERN to INVERSE

 

 

 

 

 

(negative-positive inversion).

 

 

 

 

 

 

FMKS03

 

46 4D 4B 53 30 33

Turns ON the WHITE test pattern.

 

 

 

 

 

 

FMKS04

 

46 4D 4B 53 30 34

Turns ON the RED test pattern.

 

 

 

 

 

 

FMKS05

 

46 4D 4B 53 30 35

Turns ON the GREEN test pattern.

 

 

 

 

 

 

FMKS06

 

46 4D 4B 53 30 36

Turns ON the BLUE test pattern.

 

 

 

 

 

 

FMKS07

 

46 4D 4B 53 30 37

Turns ON the YELLOW test pattern.

 

 

 

 

 

 

FRCS00

 

46 52 43 53 30 30

Sets FRC to SCALER.

 

 

 

 

 

 

FRCS01

 

46 52 43 53 30 31

Sets FRC to NORMAL.

 

 

 

 

 

 

GSL

 

47 53 4C

000

255

Adjusts the GREEN sidebar level.

 

 

 

 

 

 

IDC

 

49 44 43

Clears the display ID number (resets to

 

 

 

 

 

“ALL”); for example, 01IDC.

 

 

 

 

 

 

IDS

 

49 44 53

Sets the display ID number; for exam-

 

 

 

 

 

ple, 01IDS sets the display ID to 01h.

 

 

 

 

 

Note: IDS only works if the display ID

 

 

 

 

 

number has been cleared (with IDC) or

 

 

 

 

 

has not been previously assigned.

 

 

 

 

 

 

IPRS01

 

49 50 52 53 30 31

Sets the DISPLAY PROFILE to NOR-

 

 

 

 

 

MAL.

 

 

 

 

 

 

IPRS02

 

49 50 52 53 30 32

Sets the DISPLAY PROFILE to PURE.

 

 

 

 

 

 

IPRS03

 

49 50 52 53 30 33

Sets the DISPLAY PROFILE to MONO-

 

 

 

 

 

TONE.

 

 

 

 

 

 

IPRS04

 

49 50 52 53 30 34

Sets the DISPLAY PROFILE to HIGH

 

 

 

 

 

CONTRAST.

 

 

 

 

 

 

LESS00

 

4C 45 53 53 30 30

Sets FRONT L.E.D. to OFF.

 

 

 

 

 

 

LESS01

 

4C 45 53 53 30 31

Sets FRONT L.E.D. to ON.

 

 

 

 

 

 

Notes:

 

 

 

 

 

1.When making input-specific adjustments such as to image quality, screen position/size or audio sub-volume, select the input you wish to affect before making such adjustments.

2.These settings are not stored in memory.

62 Runco CinemaWall SP-42/-50/-60 Owner’s Operating Manual

Page 72
Image 72
Runco SP-42, SP-50, SP-60 manual FMKS00, FMKS02, FMKS03, FMKS04, FMKS05, FMKS06, FMKS07, Mal, Tone, Contrast