1 - INSTALLATION AND COMMISSIONING

LOCAL TEST

*case of underequipped unitary equipment

Equipment Inventory

-48 V power Check

Aggregate optical loopback

Insertion of communication parameters (VT100)

Setting to time and insertion of the test configuration tributary accesses

(HTTP browser)

Tributary Ports continuity check

- 48 V redundancy Check

A and B loops and alarms check

Local transmission test (30 mn) *

Optical connection

Connection of external sync input from of an "Master" equipment

(optional)

Configuration Elaboration

no

Local Test on network

 

 

of last équipment ?

 

 

yes

 

 

 

 

 

 

Link established

Optical measurements

MSP protection check

Counters reset

24 H link Performance

Equipment operational

(constitution of installation file)

Configuration Save

Figure 1-8 – Commissioning procedure for ADR155C network

Installation and User Guide - N56717020101

No reproduction or communication without the written consent of SAGEM SA

Page A1-19

Page 27
Image 27
Sagem ADR 155C manual Commissioning procedure for ADR155C network