Sagem ADR 155C manual Port safety level for the 19 subrack access, Security, Lithium Battery

Models: ADR 155C

1 134
Download 134 pages 56.83 Kb
Page 6
Image 6

PORTS SECURITY LEVEL

Port safety level for the 19" subrack access

The connectors are identified on the front panels of the equipment (cards or motherboard).

Connectors

Function

Security

 

 

level

 

 

 

PWRA/PWRB

Power supply

SELV1

 

 

 

PWR

Power supply

SELV

 

 

 

Motherboard

 

 

 

 

 

SYNC

G.703 2 Mbit/s synchronization Ports

SELV

 

 

 

E1 INPUT & E1 OUTPUT

G.703 2 Mbit/s Ports

SELV

 

 

 

MNGT

Other equipment connection

SELV

 

 

 

COMM

VT100 local supervision

SELV

 

 

 

ETH

Ethernet LAN remote supervision

SELV

 

 

 

LOOPS

Loops and remote signaling

SELV

 

 

 

ADR ICI 1.x Card

 

 

 

 

 

TR and REC

G.957 and G.958 STM-1 IC1.1 or IC1.2 Optical

Laser class 1

 

 

Dangerless

 

 

 

EOW and AUX

Engineering Order Wire

SELV

 

 

 

ADR LAN1 Card

 

 

 

 

 

ETH

Ethernet Port

SELV

 

 

 

ADR 21E120 Card

 

 

 

 

 

E1 INPUT & E1 OUTPUT

G.703 2 Mbit/s Ports

SELV

 

 

 

The 19" subrack must be mounted only in racks with a bottom part that is

)closed or fitted with a class V1 or HF1 or better air filter, or that stand on a non-flammable floor..

Safe earth requirement

This equipment must be installed only by skilled personnel. For compliance, the protective earth terminal must be connected to a safe earth with an impedance Z of less than 5 Ohms.

)Handling precaution: For any work to be carried out inside the equipment, an antistatic wrist strap must be worn.

Lithium Battery

)Warning : If the battery is incorrectly replaced there is a risk of explosion.

Only replace with same type battery or equivalent type recommanded by the manufacturer

Dispose of used battery according to manufacturer instructions

In ADR155C, battery replacement may only be done by return Supply Support Department.

1Safety Extra Low Voltage Circuit

Installation and User Guide - N56717020101

Page A0-2

Reproduction and communication in any form prohibited without the written permission of ￿