1 - INSTALLATION AND COMMISSIONING
Installation and User Guide - N56717020101
Page A1-22 No reproduction or communication without the written consent of
SAGEM SA
1.4.1 - Configuration required
The minimum configuration proposed for the operating PC is as follows:

Description Configuration 1 Configuration 2

Processor 266 MHz Pentium
Memory 32 MB 64 MB
Display 800x600, 256 colours (1024x768 recommended)
Interface Serial RS232 interface
Ethernet 10 base T network card
Operating system Windows 95 Windows NT4
Applications Hyperterminal for Windows
HTTP navigator: Netscape Communicator 4.5
1.4.2 - Parameterizing the communication function
Figure 1-9 presents the available resources and various configurations possible for the
communication function;
Connect "COMM" port of the equipment to a "COM" port not used on the PC with VT100
emulation,
Power the PC on,
Start the Hyper Terminal application
on the first use, proceed as follows:
connect "COMM" port of the equipment to a "COM" port not used on the PC,
power the PC on,
select, in succession, from Windows desktop, the Start, Programs, Acces sories and
HyperTerminal command buttons,
choose the icon representative of the HyperTerminal application,
a description window for the connection appears; give a name for the connection and
validate your choices,
a new window appears; choose that PC "COM" port which is connected to the
equipment and validate your choice,
a new window appears; configure the port parameters as indicated below and validate
the programming :
. Bits per second : 19200,
. Data bits : 8,
. Parity : no parity,
. Stop bits : 1,
. Flow control : none,
save the connection (Save command in the application File menu).
NOTE: On the next opening of "Hyperterminal" application, choosing the connection icon
will be enough to be logged on the equipment.
On the equipment power-up, the operating menu appears.
To exit the "Hyperterminal" application, select Quit command from File menu.