2 - OPERATION
Installation and User Guide - N56717020101
Page A2-20 No reproduction or communication without the written consent of
SAGEM SA
Procedure:
1. Screw off the TORX screws located on the front side, using the suited screwdriver and
unplug the card.
2. Extract the card, com plying with the measures of protection against electrostatic discharges.
NOTE: For any card handling, the operator must wear an anti-static bracelet well
tight around the wrist and earthed.
3. Package the extracted m odule in an anti-static bag.
4. Take the new module out of its anti-static bag.
5 Carefully insert the module into its place, complying with the measures of protection against
electrostatic discharges, and secure it with TORX screws
Replacing the front-panel fuse
Procedure:
1. Disconnect the power cable or the 110-240//48V 60W/ transform er from the prim ary power
source.
2. Screw off the fuse-holder f rom the power supply front panel.
3. Replace the defective fuse with an equivalent fuse, nam ely:
4A quick-break fuse (HA214A)
Dimensions length: 20mm ± 0.5
diameter: 5.2 mm +0.1/-0.2
4. Screw the fuse-holder.
5. Reconnect the power cable or the 110-240//48V 60W/ transformer to the primary power
source