2 - OPERATION

Alarms

 

Description

Severity

LPT : Lower order Path Termination

 

SD-V5 (VC12)

 

Signal Degrade –V5

minor

 

 

 

 

SD-B3 (VC3)

 

Signal Degrade –B3

minor

 

 

 

 

LO-SLM

 

Low order Path – Signal Label Mismatch

Non-alarmed

 

 

 

 

LO-RDI

 

Low order Path – Remote Defect Indication

minor

 

 

 

 

LO-UNEQ

 

Low order Path – Unequipped

Non-alarmed

 

 

 

LPA : Lower order Path Adaptation

 

LO-SLM

 

Low order Path – Signal Label Mismatch

Non-alarmed

 

 

 

PPI : PDH Physical Interface

 

LOS

 

Loss Of Signal

minor

 

 

 

 

AIS

 

Alarm Indication Signal

Non-alarmed

 

 

 

SETS : Synchronous Equipment Timing Source

 

T3 LOS

 

Loss Of Signal on T3 sync input

minor

 

 

 

 

T1 LOS

 

Loss Of Signal on T1 sync input

Non-alarmed

 

 

 

 

T2 LOS

 

Loss Of Signal on T2 sync input

Non-alarmed

 

 

 

 

T4 - Failure

 

Failure on T4 synchronization output

minor

 

 

 

 

Local equipment

 

 

Local user

 

Remote indication 1

Non-alarmed

inputs # 1

 

 

 

 

 

 

 

Local user

 

Remote indication 2

Non-alarmed

inputs # 2

 

 

 

 

 

 

 

Local user

 

Remote indication 3

major

inputs # 3

 

 

 

 

 

 

 

Local user

 

Remote indication 4

minor

inputs # 4

 

 

 

 

 

 

Remote equipment

 

Far user inputs

 

Remote indication 1

Major *

# 1

 

 

 

 

 

 

 

Far user inputs

 

Remote indication 2

Minor *

# 2

 

 

 

 

 

 

 

Others

 

 

Message

 

Card configuration

major

 

 

 

 

Message

 

Defective card

major

 

 

 

 

Message

 

Missing card

major

 

 

 

 

Table 2-10 : Alarms and severity (2/2)

*If the equipment configured is declared centre site.

Installation and User Guide - N56717020101

Page A2-14

No reproduction or communication without the written consent of SAGEM SA

Page 50
Image 50
Sagem ADR 155C manual LPT Lower order Path Termination, LPA Lower order Path Adaptation, PPI PDH Physical Interface